Connection To A Secondary User Interface - Jandy JE Serie Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

|
Jandy
®
JE Heat Pumps
5.
Use 22 gauge 4-conductor wire (Zodiac
4278) to run between the heat pump and the RS
control, and match the wire color order.
6.
The wires coming from the Jandy JE heat pump
can be "doubled up" on the red terminal bar
with the four (4) wires coming from the indoor
controller.
NOTE If you need to install more than two (2) wires in
each terminal, order a Zodiac
Kit, which includes the Multiplex Board (Zodiac
Part No. 6584). Never put more than two (2)
wires into each of the pins of the terminal bar.
7.
Check all wiring, then apply power to both the
heat pump and the RS control system. Operation
can be verified in either Service or Auto mode. See
the RS Control System manual for instructions
about operation.
When the Jandy JE heat pump is first powered and
there is an RS control connected to the heat pump,
the display on the heat pump will show "JANDY
REMOTE ONLINE PUSH MENU TO DISABLE" .
When the JE heat pump is online with the RS control,
all functionality of the control on the heat pump is
disabled. The heat pump functions can be controlled
only at the RS unit.
To temporarily use the heat pump controls, press
the
button. The message "JANDY REMOTE
MENU
ONLINE PUSH MENU TO DISABLE" will disappear
from the heat pump display. All functionality has now
been returned to the control on the heat pump. In this
mode the RS unit is no longer controlling the heat
pump.
AquaLink Touch
Thu January, 2009 3:03 PM
Pool Temp
Air Temp
86º
78º
FILTER
SPA
POOL
SPA
AUX1
AUX2
AUX3
Other
HEAT
HEAT
Devices
PUMP
On/Off
Home
Menu
OneTouch
Help
Back
Status
Photos
Power
Green - Enabled
Red - On
S1
S2
Figure 12. AquaLink RS to Jandy JE Heat Pump - T-Stat (2 wire) connection
Installation and Operation Manual
Part No.
®
Multiplex PCB
®
Green - Enabled
Red - On
4 3 2 1
4 3 2 1
S1
RESET
OFF
ON
AUTO
SERVICE
TIME OUT
S2
DIP Switches
OFF
ON
S1 and S2
To return the functionality to the RS unit, cycle (turn off
and then turn on) the power to the heat pump, or press
the MENU button for 5 seconds to enter the User Setup
Mode and then enable the Zodiac Remote.
NOTE If connecting more than two (2) items to the RS
Power Center red, 4-pin connector, a Multiplex
PCB is required.

Connection to a Secondary User Interface

1.
Turn off the power to the heat pump.
2.
Remove the five (5) screws that attach the front
panel to the heat pump and remove the cover to
the junction box. See Figure 10.
3.
Run four (4) 22 AWG solid copper wires into the
conduit labeled "Low Voltage Connection" located
on the lower right hand side of the heat pump. See
Figure 10. The wires may be up to 300 feet
(91.4 m) in length.
4.
Connect the wires to the 4 position terminal on
the upper left hand corner of the Power Interface
PC Board, labeled "User Interface1". The wires
will be added to the existing wiring to the User
Interface installed on the heat pump.
5.
Ensure the wiring is consistent when connecting
the wires to the second User Interface. For
example, BK goes to BK, O goes to O, etc.
6.
Re-install the junction box cover and service
access panel and restore power to the heat pump.
Heat Pump
Heat Pump Connections
Terminals 1 and 2
6 5 4 3 2 1
10 9 8 7 6 5 4 3 2 1
RS6 & RS8 ONLY
RS8 ONLY
POOL MODE
SPA MODE
SPA DRAIN
HEATER
SOLAR
SPA FILL
ENGLISH
Page 17