Dräger X-plore 4740 Instrucciones De Uso página 9

Semicareta
Ocultar thumbs Ver también para X-plore 4740:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
— Strictly follow the national regulations for the use of respiratory
protective devices (in Germany for example BGR 190,
in Australia and New Zealand for example AS/NZS 1715:1994
"Selection, use and maintenance of respiratory protective devices").
— The filter apparatus set is suitable for use by instructed personnel only!
— When using the half mask in explosion-hazard areas, treat with antistatic
spray or apply a water film.
— Temperature during use: -30 to 60
Selection for the use of respiratory filters
The following filters approved according to EN 14387:2004 and
EN 143:2000 or AS/NZS 1716 with a maximum weight of 300 g and a
connection in accordance with EN 148-1 can be used:
— Particle filters
— Gas filters
— Combined filters
As an alternative, you can connect the purifying respirators X-plore 7300,
X-plore 7500 and Panorama BelAir GC or the compressed air hose units
Abil-R and X-plore 9000.
Use
The don procedure differs depending on whether the half mask is used in
combination with a respiratory filter or a purifying respirator or hose
breathing apparatus.
Half mask with respiratory filter (F)
Screw in the respiratory filter.
Don the half mask (see below).
Check whether the system is leak-tight (F):
Use your hand to seal the respiratory filter and inhale until negative
pressure is generated.
Hold your breath for a moment.
The mask must hold the negative pressure, if not:
Retighten the straps or use another mask size.
o
C
Half mask with purifying respirator or hose breathing apparatus (E)
Don the half mask (see below).
Check whether the breathing connection is leak-tight (E):
Use your hand to seal the filter connection and inhale until negative
pressure is generated.
Hold your breath for a moment.
The mask must hold the negative pressure, if not:
Retighten the straps or use another mask size.
Screw in the purifying respirator or the hose breathing apparatus.
Don the half mask (B, C, D)
Half mask with head straps (B1, C1, D1):
Loosen the harness:
Pull the ends of the harness as far as possible towards the head straps.
Push the half mask up to the head straps.
Close the locking hooks (B1).
Fit the half mask over your mouth and nose. Pull the head straps over your
head and position them on the back of your head (C1).
Pull the ends of the harness until the half mask sits tight on your face (D1).
Half mask with headband (B2, C2, D2):
Loosen the headband:
Lift the lug with your thumb and pull the headband as far as possible in the
direction of the arrow (B2).
Fit the half mask over your mouth and nose (C2).
Position the headband on the back of your head and guide the harness
over your ears in the process.
Pull the ends of the headband until the half mask sits tight on your
face (D2).
Beards or drooping cheeks can affect the required leak-tight fit of the half
mask. Danger of intoxication!
Use with leak-tight half mask and installed respiratory filter only!
CAUTION
9

Publicidad

Tabla de contenido
loading

Tabla de contenido