8.4
To empty the spent mandrel container
•
The container must be emptied in good time; overfilling will cause malfunctions.
9.
Maintenance and care
•
The complete grip mechanism must be maintained regularly.
•
Never operate the trigger with no grip mechanism fitted. As this could cause serious dam-
age to the tool.
•
Regularly check the compressed air and hydraulic connections as well as the hoses. If
damaged, have replaced by a skilled technician.
•
The hoses should not be in operation for longer than 6 years, including the maximum
storage time of 2 years.
9.1
To oil jaws and clean steel head sleeve
•
Disconnect the blind rivet setting tool from the compressed air supply.
•
Unscrew steel head sleeve (B).
•
Dip the complete gripping mechanism into an oil bath as far as the O-ring (C) or wet the
jaws (E) with oil and allow to drip off
•
Clean steel head sleeve (B)
•
Reassemble in reverse order.
9.2
To change jaws
•
Disconnect the blind rivet setting tool from the compressed air supply.
•
Unscrew steel head sleeve (B).
•
Unscrew jaw housing (D).
•
Remove jaws (E).
•
Clean jaw housing (D) and grease sliding surfaces.
•
Fit new jaws (E) from the front (they are held by the grease).
•
Reassemble in reverse order, ensuring that all parts are fixed tight.
GB
19