To empty the spent mandrel container

The container must be emptied in good time; overfilling will cause malfunctions.
9.

Maintenance and care

The complete grip mechanism must be maintained regularly.
Never operate the trigger with no grip mechanism fitted. As this could cause serious dam-
age to the tool.
Regularly check the compressed air and hydraulic connections as well as the hoses. If
damaged, have replaced by a skilled technician.
The hoses should not be in operation for longer than 6 years, including the maximum
storage time of 2 years.
9.1

To oil jaws and clean steel head sleeve

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (B).
Dip the complete gripping mechanism into an oil bath as far as the O-ring (C) or wet the
jaws (E) with oil and allow to drip off
Clean steel head sleeve (B)
Reassemble in reverse order.
9.2

To change jaws

Disconnect the blind rivet setting tool from the compressed air supply.
Unscrew steel head sleeve (B).
Unscrew jaw housing (D).
Remove jaws (E).
Clean jaw housing (D) and grease sliding surfaces.
Fit new jaws (E) from the front (they are held by the grease).
Reassemble in reverse order, ensuring that all parts are fixed tight.