Repairs; Troubleshooting; Blind Rivet Is Not Set; Spent Mandrel Is Not Evacuated - Gesipa TAUREX 1-4 Axial Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 33

10. Repairs

Repairs under warranty are carried out by the manufacturer. Repairs outside the warranty
period should only be carried out by skilled technical personnel. Failure to observe the as-
sembly and setting procedures and operation by non-skilled personnel may result in serious
damage to the blind rivet setting tool. In case of doubt, always send the blind rivet setting tool
back to the supplier or to GESIPA

11. Troubleshooting

11.1 Blind rivet is not set

Cause
Jaws (E) dirty
Jaws (E) worn
Insufficient working pressure
Tool stroke too low

11.2 Spent mandrel is not evacuated

Cause
Spent mandrel container full
Mandrel evacuation hose blocked
Wrong nosepiece (A) used
Nosepiece (A) worn
Spent mandrel jammed in jaws (E)

12. Warranty

The applicable terms and conditions of guarantee shall apply and can be viewed under follow-
ing link: www.gesipa.com/agb
.
®
Corrective measures
Clean and oil sliding surfaces (Point 9.1)
Replace (Point 9.2)
See working pressure (Point 5)
Top up with hydraulic oil (Point 9.3)
Corrective measures
Empty (Point 8.4)
Empty (Point 8.4)
Replace according to table (Point 7)
Replace
Clean jaws (E) and jaw housing (D) and oil sliding
surfaces; replace if worn (Point 9.2)
GB
21

Publicidad

Tabla de contenido
loading