MAINTENANCE AND DIAGNOSIS OF FAILURES

1

MAINTENANCE

Before
carrying
operation, disconnect the device from the
power supply.
O
If you have to dismount the operator from its
supports, first tighten the discharge screw in
order to prevent the hydraulic fluid from
leaking.
2

FAILURE DIAGNOSIS

Problem
The operator does not make any
movement when the opening or
closing transmitters are activated
By activating the opening or closing
controls, the operator is enabled but
the gate does not move
The gate moves in an irregular manner
The gate cannot completely close (or
open)
3

SPARE PARTS

If the operator needs repairing, go to an
authorised assistance centre or manufacturer;
never try to repair it yourself.
4

SCRAP

The operator, up until the end of its useful life,
must be dismounted at its location by an
installer who is as well qualified as the person
who completed the assembly, observing the
same precautions and safety measures. In this
manner we will avoid possible accidents and
damage to adjacent facilities.
54
Installation manual
out
any
maintenance
Cause
Absence of system power voltage
Defective electrical installation
Defective control panel or control
devices
Defective capacitor
The assembly dimensions of the
supports have not been respected.
The operator is not horizontal
The photocell detects an obstacle
T h e r e s i s t a n c e o f t h e g a t e h a s
increased when closing (or when
opening)
The force of the operator during
closing (or opening) is too low
The assembly dimensions of the
supports have not been respected.
1 Regularly check installation in order to discover any
imbalance or signs of deterioration or wear. Do not use
the device if any repair or adjustment is necessary.
2 Clean and lubricate the articulations of the gate, so
as not to increase the effort of the operator.
3 Check that the transmitters and photocells, as well
as their installation, have not suffered any damage
from the weather or external agents.
Solution
Re-establish the power supply voltage
Check that the installation does not
present any short-circuits or cut-off points
Check these elements, seeing their
respective manuals
Check the state of the capacitor
Dismount the supports and then put them
back in place, respecting the assembly
dimensions
Dismount the supports and then put them
back in place, respecting the height
difference of 19 mm
Eliminate the obstacle and try again
Check the moving parts of the gate and
eliminate the resistance
U s e t he o p e n i n g a nd c l o s i n g f or c e
adjustment screws to increase the force
when opening and closing
Dismount the supports and then put them
back in place, respecting the assembly
dimensions
Use only original spare parts.
}
The operator must be deposited in the appropriate
containers for subsequent recycling, separating and
classifying the different materials in line with their
nature. NEVER deposit it in domestic rubbish or in
landfills which are not controlled, as this will cause
environmental damage.