LCD Display (fig.15)
A
"PROGRAMME MENU" AREA
B
"STATUS LINE" AREA
"UNBALANCE" AREA (unbalance extent
C
and position)
"ACTIVE OR SUGGESTED FUNCTIONS"
D
AREA
WHEEL DATA ENTRY
Wheel data entry for wheel
balancers without an ultrasonic
sensor
The machine allows for the diameter and distance
values to be entered automatically; the width
value can be entered using the keypad.
- Bring the automatic measuring arm into contact
with the inner side of the rim (fig.16).
EM 9550 - Operator's manual
Take great care to position the arm correctly
so as to ensure accurate data reading.
While moving the automatic arm, the distance
measured by the arm is shown on the display:
15
When the measurement is stored, the value of
the distance acquired by the machine will remain
visible on the left display:
- if only one measurement is taken, the machine
interprets the presence of a rim with balancing
using a clip weight on both sides (Dynamic
Balancing Programme)
- moving the arm to the rest position, the machine
will set up for the manual WIDTH entry.
- in this phase, it is possible to perform an ad-
ditional acquisition of the rim diameter and
distance.
- Measure the width of the rim using the calliper
provided (fig.17).
16
16a
UK
16b
53