- Unscrew the C hub completely;
- Mount the flange on the shaft and lock it with
the two screws (A, fig.19) using the CH 6 wrench;
A
- Lock the wheel onto the flange as usual.
C hub mounting
Proceed as follows to remount the C hub:
- Keep the
3 seconds to lock the wheel-holder shaft and
the internal devices.
- Screw the C hub manually until it reaches the
end position.
- Tighten the C hub by inserting the C special
wrench into the C hub hole (fig.20).
56
18
19
button pressed for at least
20
UNBALANCE
VISUALISATION IN
GRAMMES/OUNCES
Perform the following procedure to set the visuali-
sation of the unbalance values in grams or ounces:
- Press the
gramme menu.
- Use the
cursor.
- Select the
programme icon.
- Press the
button to change the setting.
- Press the
button to confirm selection
and exit the programme menu.
ROUNDING-OFF
When started up, the machine is set to display
the unbalance values at five-gramme increments,
i.e. rounded to the nearest multiple of five (or
quarters of an ounce if visualised in ounces).
Under this condition, the first four grams of unbal-
ance are not displayed since a suitable threshold,
indicated on the LCD display in the status line,
is activated
This setting can be changed from grx5 to grx1 (from
oz/4 to oz/10) either permanently or temporarily.
Rounding off permanently
Perform the following procedure to change the
unbalance value visualisation from grx5 to grx1
(from oz/4 to oz/10) or vice-versa:
- Press the
gramme menu.
- Use the
cursor.
- Select the
programme icon.
EM 9550 - Operator's manual
button to access the pro-
buttons to move the
.
button to access the pro-
buttons to move the