Declaration of conformity: scale line Panda7/X
We, Mettler-Toledo (Changzhou) Scale & System Ltd., hereby declare with sole responsibility that the Panda7/X scales
to which this declaration applies conform to the following EU directives and standards:
Marking
0032
FM
APPROVED
ia
0032
0032
Mettler-Toledo (Changzhou) Sacle & System Ltd.
111 Changxi Rd. Changzhou, Jiangsu 213001, PRC
September 2005
USA
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to both Part 15 of the FCC
Rules and the radio interference regulations of the Canadian Department of Communications. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful
interference, in which case the user will be required to correct the interference at his own expense.
Canada
ICES-001 Notice for Industrial, Scientific and Medical Radio Frequency Generators: This ISM apparatus meets all requirements of the
Canadian Interference-Causing Equipment Regulations. Please note that this requirement is only for generators which operate at over
10 kHz.
Avis de l'ICES-001, générateurs de radiofréquences dans le domaine industriel, scientifique et médical: Cet appareil ISM (industriel,
scientifique et médical) satisfait à toutes les exigences définies par la réglementation canadienne en matière d'équipements générant
des perturbations radioélectriques. Veuillez noter qu'il s'agit d'une exigence concernant uniquement les générateurs fonctionnant au-
delà de 10 kHz.
EU directive
94/9/EEC (ATEX)
73/23EEC low voltage
89/336EEC EMC
Tested to standard
EN50014, EN50020
FMRC 3600, 3610, 3810
CSA-C22.2 No. 157-92
CSA-C22.2 No. 142-M 1987
EN61010-1
EN61326-1 Emission Cl. B
EN61326-1 Immunity
AS/NZS2064.1/2, AS/NZS3548
AS/NZS4251.1, AS/NZS4252.1
David Zheng
President
Chu Jinlan
Quality Assurance Manager