ADDITIONAL THERMOSTAT
N.B. : Installation must be performed by an authorised technician.
There is a possibility to thermostat a room adjacent to the room where the stove is positioned: just connect a thermostat following the procedure
described in the next step (it is recommended to position the optional mechanical thermostat at a height of 1.50 m from the oor) . Stove
functioning with the external thermostat connected in the TA clamp can be di erent on the basis of the activation or disabling of the STBY
function.
The TA clamp leaves the factory jumpered, therefore it is always with closed contact (on request).
ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY ACTIVE
When the STBY function is activated, the
reached), the stove will switch o . As soon as the contact or external thermostat switches to the "not satis ed" status (closed contact/
temperature to be reached) it will re-ignite.
N.B.: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If the stove
is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT FUNCTIONING WITH STBY DEACTIVATED
When the STBY function is disabled, the
When the contact or external thermostat is satis ed (open contact / temperature reached), the stove will go to minimum. As soon as the
contact or external thermostat switches to the "not satis ed" status (closed contact / temperature to be reached) the stove will start to work
again at the pre-set power.
N.B.: stove operation depends on the temperature of the water inside the stove and relative factory setting restrictions. If the stove
is in H OFF (water temperature reached), any additional contact or thermostat request will be ignored.
ADDITIONAL THERMOSTAT INSTALLATION
� Switch the appliance o using the master switch positioned on the rear of the stove.
� Remove the plug from the socket.
� Refer to the electrical layout to connect the two thermostat cables to the relative clamps positioned on the rear of the machine, one is
red and the other black (TA clamp). Every model can have a di erent position of the relative clamps in the rear of the machine. The
image is given as an example.
REFER TO THE ''SETTINGS'' CHAPTER TO ACTIVATE STAND BY
LED ashes. When the contact or external thermostat is satis ed (open contact / temperature
LED is xed.