Dal Zotto MARTA IDRO 2.0 Manual Del Usuario página 57

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

FUMES PROBE
Fumes probe failure.
HOT FUMES
High ue gas temperature
The door is not closed correctly.
The ash drawer is not closed correctly.
ALL CLEAN CHECH UP
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
The pellet feed-box is empty.
NO
Pellet feed calibration inadequate.
IGNITION
Thermostat bulbs tripped
NO IGNITION
No current during the ignition phase.
BLACK OUT
The pellet feed-box is empty.
NO PELLETS
No pellet feed.
The motor reducer does not feed pellets.
The door is not closed correctly.
The ash drawer is not closed correctly.
DEPRESSION ALARM
The combustion chamber is dirty.
The ue exhaust pipe is blocked/dirty.
DEBIMETER
Flow sensor faulty.
FAULT
Sensor disconnected
Air in the system
H20 OVERTEMP
Unsuitable circulation
The automatic burn pot cleaning is blocked.
* TRAPDOOR FAULTY
Burn pot dirty or clogged
The door is not closed correctly.
ALL MIN H2O PRES
The system pressure read by the pressure switch
SURE
is too low.
H2O PROBE
H2O probe failure
ALL MAX H2O PRES
The pressure of the water has exceeded the max
SURE
threshold
* PRESSURE SENSOR
Defective, disconnected or faulty di erential
FAULTY
pressure sensor.
* AUGER CONTROL
Anomalous pellet loading.
* AUGER BLOCK
Anomalous functioning of the motor.
* BOILER PROBE
Boiler probe failure.
* PUFFER PROBE
Boiler probe failure.
The pellet feed-box is empty.
The door is not closed correctly.
* TANK EMPTY
The ash drawer is not closed correctly.
The combustion chamber is dirty.
The ue exhaust pipe is blocked.
* on applicable models
Contact after-sales centre
Check pellet feed (see "Pellet feed adjustment"). If the problem cannot be
solved, contact an authorised technician.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air channel
and the combustion chamber.
Check for the presence of pellets in the feed-box.
Adjust pellet ow (see "Pellet feed adjustment").
Check the procedures described in the "Ignition" chapter.
Check the bulb thermostats (see Rearms chapter)
Set the stove on OFF using key 1 and repeat the procedure described in the
"Ignition" chapter.
Check for the presence of pellets in the feed-box.
Adjust the pellet ow (see "Pellet feed adjustment").
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe and the combustion chamber.
Contact after-sales centre
Possible air in the system, vent the system.
Lack of adequate circulation.
Lack of or inadequate safety zone.
The water in the stove has exceeded 95°C.
Possible circulator anomaly.
If the problem persists, the reset operations must be carried out by an
authorised technician.
Check closure of the door.
Check that the burn pot is clear and clean.
The automatic burn pot cleaning is blocked.
If the problem persists contact the service centre
Possible air in the system, vent the system.
Possible lack of water or leaks due to anomalies in some system component.
If the problem persists contact the service centre
Contact after-sales centre
Possible air in the system, vent the system.
Check that the expansion vessels are not damaged or under-dimensioned
Check that the cold system is loaded at the correct pressure
If the problem persists contact the service centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Contact after-sales centre
Check for the presence of pellets in the feed-box.
Check hermetic door closure.
Check hermetic closure of the ash drawer.
Check cleanliness of the fumes pipe, of the sensor in the primary air
channel and the combustion chamber.
Contact after-sales centre
ENGLISH
57

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jole idro 2.0

Tabla de contenido