RESET

Allows the user to reset all values modi able by the user to the default values.
CONTROLS PROCEDURE
Press key 6.
Proceed by pressing key 2 until USER MENU is displayed.
Con rm using key 6.
Press key 2 until RESET is displayed.
Press keys 4-5 to select ON and press key 6.
''DONE'' will appear on the display to con rm

EASY SET UP

The volumetric weight of the pellet is the ratio between the weight and the volume of the pellet. This ratio may change while maintaining the
quality of the pellet. Using the EASY SET UP function, it is possible to vary the calibration of the volumetric weight by increasing or decreasing
the pre-set values.
In the stove program, the values available range from "– 3" to "+ 3"; all the stoves are calibrated in production with the optimal value of 0.
Where excessive depositing on the burn pot is evident, enter the EASY SET UP program and lower the value of a unit to "- 1" then wait until the
following day and if there is no improvement decrease further to a maximum of "- 3". Where instead it is necessary to increase the calibration
of the volumetric weight of the pellet, change the default value of "0" to "+ 1, + 2 or + 3" according to requirement.
EXCESSIVE DEPOSITING OF PELLET IN THE BURN POT
-3
-2
THIRD RANGE OF
SECOND RANGE
DECREASE IF THE
OF DECREASE
FIRST TWO ARE
IF THE FIRST IS
INSUFFICIENT
INSUFFICIENT
N.B.: Where these settings do not correct pellet depositing in the burn pot, please contact your local support centre.
CONTROL PROCEDURE
Press the 6 key.
Continue pressing the 2 key until you see USER MENU.
Con rm with the 6 key.
Press the 2 key until you see "EASY SET UP".
Use the 4-5 keys to increase (4) or decrease (5) the load during the WORK
phase.
Press the 1 key several times to con rm and exit the menu.

SET CHRONO

This stage is used to program when the generator automatically turns on and o .
The factory setting for SET CHRONO is disabled on the generator.
The chrono allows the user to program 4 time spans within a day to use every day of the week.
The switch-on and switch-o time can be set in every time slot, along with the days of use of the programmed time slot and the
desired water temperature (65 - 80°C).
The setting of the current day and time is essential to ensure the chrono operates correctly.
RECOMMENDATIONS
Before using the chrono function, set the current day and time. Therefore check that the points listed in the "Set clock" sub-chapter have been
followed, so that the chrono function works. Aside from programming it, activate it as well.
The ignition and switch-o times must be within the arc of one day, from 0 to 24 and not over several days.
Example:

NORMAL OPERATION

-1
FIRST RANGE OF
OPTIMAL FACTORY
DECREASE (TEST
VALUE
FOR 1 DAY)
CORRECT
Switch-on time 07:00
Switch-o time 18:00
ENGLISH
LOW DEPOSITING OF PELLET IN THE BURN POT
0
+1
FIRST INCREASE
RANGE
+2
SECOND INCREASE
THIRD RANGE OF
RANGE IF THE
INCREASE IF THE
FIRST IS INSUFFI-
FIRST TWO ARE
CIENT
INSUFFICIENT
INCORRECT
Switch-on time 22:00
Switch-o time 05:00
+3