5.1.7) Carry out the functional check on the cable. 5.2) Functional
check attached to the cable: A) Hold the runner attached to the cable
by the carabiner and pull up. When the carabiner is pulled upwards
vertically and slowly moved up and down, the runner should follow the
movements easily on the cable. Diagram 7 B) If the carabiner is let go
or pulled back down, the runner should lock and clamp to the cable!
Diagram 5
5.2) Remove the runner in the same way as it was inserted, but in the
reverse order. The design makes it impossible to insert the runner
incorrectly (back to front) and it cannot be opened and/or attached
and then closed. The arrow on the top of the runner shows the correct
direction and must always point upwards.
5.3) Cable guides:
5.3.1) Transferable cable guides: Cable guides can be transferred
from the runner without having to remove the runner from the cable
and without having to release the cable from the intermediate bracket.
To allow the runner to glide over the cable guide, ensure as far as
possible that the runner is not twisted. Diagram 3
5.3.2) Non-transferable cable guides: If cable guides are not
transferable, you will need to climb up to just before the cable guides
and pull the cable out of the guide. You can then climb over the guide
and introduce the cable back into the cable guide beneath the runner.
Cable opening on the side. Diagram 11
Cable opening in front. Diagram 12
6.) Use of the climbing protection system
6.1) Observe the operating temperature range (-30°C to +45°C)
6.2) In extreme conditions which can include climatic con-ditions, the
effect of chemicals or mechanical influences, e.g. sharp edges, oil, ice
etc., use of the fall-arrest system is not recommended.
6.3) Carry out a visual check of the cable and ladder attachments
before/during climbing to ensure everything is complete and in
satisfactory condition.
6.4) Intermediate cable brackets must be firmly attached to the rungs
and must not bend the cable. When climbing up or down, the runner
must always be directed ("towed") under its attachment point on the
harness in order to keep the runner moving freely (towing mode
Diagram 7). Climb up or down slowly and evenly and bring the runner
with you. However, do not leave your hand on the shock absorber/
carabiner or runner! Runners must not be used as a working position.
Separate PPE systems
(e.g. EN 358 and EN 354/355) should
be used for this purpose. Before removing the runner, ensure you
have a secure footing on a platform and, in areas where there is a risk
of falling, fall arrest lanyards
(e.g. EN 354 / 355) attached to a
suitable anchor point. If several people are using the climbing