Toro EVOLUTION AG Manual Del Usuario página 22

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Erase Schedule – Reset the selected schedule.
ENABLED) and the schedule TYPE set to WEEKDAYS. All other settings within the schedule will be set to OFF.
Step 1
– While in the ADVANCED/SCHEDULE DETAILS menu, use the Up
want to edit. Press SELECT
Step 2
– Use the Up
or Down
– Use the Up
or Down
Step 3
Set MV/Pump Delay – Set a wait time between activating the master valve or pump, and activating the rst valve in the schedule.
is delay is usually used to allow the system enough time to build pressure for proper operation, or to ll the irrigation piping system with
water.
Step 1
– While in the ADVANCED/SCHEDULE DETAILS menu, use the Up
want to edit. Press SELECT
Step 2
– Use the Up
or Down
– Use the Up
or Down
Step 3
Set Valve Delay – Set a wait time after a valve closes and before another valve is activated.
system is being fed by a well.
Step 1
– While in the ADVANCED/SCHEDULE DETAILS menu, use the Up
want to edit. Press SELECT
Step 2
– Use the Up
or Down
Step 3
– Use the Up
or Down
between 10 seconds to 30 minutes in 10-second increments. Press SELECT
Set MV/Pump In Delay – Set whether the master valve or pump is active during valve delays.
Step 1
– While in the ADVANCED/SCHEDULE DETAILS menu, use the Up
want to edit. Press SELECT
– Use the Up
or Down
Step 2
Step 3
– Use the Up
or Down
delays. Press SELECT
Note:
is function is used when a well needs time to recover between valve openings. For example, a schedule includes Valve 1 and
Valve 2. A VALVE DELAY of 10 minutes has been programmed. Valve 1 opens, irrigates, and closes.
e grower's desire in this example is for the pump to be o during this 10 minutes before Valve 2 opens to allow the well to recover, so he
would set the MV/PUMP IN DELAY to OFF.
between Valve 1 and Valve 2.
18
e schedule's status will be set to DISABLED (except for schedule A, it remains
.
arrows to navigate to ERASE SCHEDULE, then Press SELECT
arrows to Yes to proceed to erase the schedule or No to cancel, then press SELECT
.
arrows to navigate to MV/PUMP DELAY. Press SELECT
arrows to adjust the delay time as necessary. Press SELECT
e delay allows the well time to recharge. Valve delay can be set with a maximum duration of 30 minutes.
.
arrows to navigate to VALVE DELAY. Press SELECT
arrows to adjust the delay time as necessary.
.
arrows to navigate to MV/PUMP IN DELAY. Press SELECT
arrows to set the MV/Pump In Delay to ON or OFF during valve
.
is ensures that the MV/Pump relay will be o during the 10 minutes of VALVE DELAY
or Down
arrows to select the Schedule you
ERASE SCHEDULE
.
ARE YOU SURE?
or Down
arrows to select the Schedule you
SCHEDULE A
.
ERASE SCHEDULE
MV/PUMP DELAY
.
VALVE DELAY
is delay is commonly used when the
or Down
arrows to select the Schedule you
.
MV/PUMP DELAY
VALVE DELAY
e delay can be set
MV/PUMP IN DELAY OFF
.
e default is set to OFF.
or Down
arrows to select the Schedule you
SCHEDULE A
.
MV/PUMP DELAY
VALVE DELAY
MV/PUMP IN DELAY
e 10 minute Valve Delay begins.
NO
.
00:10
OFF
SCHEDULE A
OFF
00:10
OFF
OFF
ON