3- Connect one end of the suction tube (2) to the PH control left hole, input
(11).
4- Connect the other end of the suction tube (2) to the suction filter (4).
5- Place the suction filter (4) inside the ACID deposit.
6- Connect one end of the suction tube (3) to the PH control right hole, output
(12).
7- Place the pipe nibble (9) inside the flange (10).
8- Place the injector (8) inside the pipe nipple (9).
9- Connect the other end of the injection tube (3) to the injector (8).
10- Place the probe holder (6) inside the flange (7).
11- Place the PH probe (5) inside the probe holder (6).
12- Place the PH probe (5) connector in the BNC connector (13) of the
equipment.
3.2.3- ADVANCED kit (Redox)
The equipment continuously measures the bactericide level of water through
this probe, by means of a "Redox" probe. Simply adjust the required level and
the equipment automatically maintains the level of disinfection by adjusting the
production of chlorine to the real needs of the swimming pool.
The screen shows the "Redox" level (bactericide capacity) present in the
swimming pool.
The potential RedOx (Reduction Oxidation) or ORP (Oxidation Reduction
Potential) is the electrical voltage that indicates the oxidation capacity or
reduction of a solution. In swimming pools, the oxidation capacity is directly
related to the bactericide power of the water, which is directly related to the
concentration of free chlorine in the pool.
This probe allows you to adjust the equipment in AUTOMATIC operation mode.
3.2.4.1- Parts
Manual EVOLINK v.5
REDOX Probe
5- Probe-Holder
6- Flange (kit does not provide it)
4- Reference liquid 465mV.