To reset the R134a Log manually, execute the following
procedure.
i
We recommend that the R134a log be printed before
resetting manually.
1. Select "R134a Log" in the Service Record menu.
2. Select "Monthly".
i
Only monthly R134a logs can be reset.
3. Select the month for which you wish to view the
R134a log.
� to reset the R134a log.
4. Press
The following screen is displayed.
73738
5. Enter the password:
"
The R134a log is reset.
Robert Bosch GmbH
.
Maintenance | ACS 651/751 | 117
7.3.4
Transferring the R134a record to a USB disk
1. In the Service Record menu, select "R134a Log"
and press E.
2. Select "Transfer R134a Movement Report" and
press E.
71342
3. Enter the password:
The
following warning message is displayed.
4. Press E.
The following screen is displayed.
!
The USB disk is formatted during data transfer and
any data, if present, will be lost. Ensure that the
existing data in the USB disk is transferred to a PC
or laptop and stored before connecting the USB disk
to the ACS 651/751.
5. Connect the USB disk to the USB port on the
ACS 651/751.
!
Before transferring the R134a records, ensure that
the USB disk is properly inserted in the USB port.
en
.
|
1 689 988 238
2012-11-06