6.2 Technical specification
Type: RKPowerlift M
Basic surface (L x W)
Height
Lift
Weight
Supply voltage
(primary)
Control board
Transformer output
Protection class
Electrical connection
Max. power
consumption
Lifting speed
Duty cycle
Protection category
Continuous sound
pressure level
max. power
consumption
Primary fuse
max. compressive /
tensile force
Torque loading
(dynamic)
Bracing moment
(static)
Service life
Operating
environment
Transport and storage
conditions
Start/Stop
Start/Stop
1200 N
1500 N
210 - 710 mm
529 mm
(see type plate)
0 - 500 mm
240 mm
(see type
plate)
ca. 12,5 kg
100/115/120/230 Vac 50/60 Hz
Control board PL M V x.y
75 VA
Cold device socket in accordance with
IEC 60320-C13
1,5 A
max. 13 mm/sec.
15 % at 10 minutes (1.5 minutes operation / 8.5 minutes pause)
With entire surface and cover without drilled holes, the stand and application sur-
faces achieve the protection class IP 30. Installation of the RK SyncFlex adapter plates
150 VA
T 2.5 AL, 250 V (RK Powerlift M
without device socket)
T 2.5 AL, 250 V
T 6.3 AH, 250 V (RK Powerlift M
1200 N/750 N
1500 N/750 N
min. 10,000 double strokes (1 double stroke = 1 x upwards, 1 x downwards)
6. Product information
Start/Stop
1500 N
190 x 150 mm
210 - 610 mm
(see type plate)
0 - 400 mm
(see type plate)
12 - 15 kg (depending on design)
I
max. 10 mm/
sec.
achieve the protection class IP 20.
less than 60 dB (A)
with device socket)
3000 N/750 N
Mmax. = 200 Nm
Mmax. = 400 Nm
Temperature: +5 °C to +40 °C
Humidity: 30% to 75% (no thawing)
Air pressure: 700 hPa to 1060 hPa
Temperature: -20 °C to +60 °C
Humidity: 30% to 85% (no thawing)
Air pressure: 700 hPa to 1060 hPa
Ext. control
Ext. control
1500 N
3000 N
210 - 710 mm
210 - 610 mm
(see type plate)
(see type plate)
0 - 500 mm
0 - 400 mm
(see type plate)
(see type plate)
24 Vdc
–
–
III
External 8-pin DIN plug
3,5 A at U = 24 Vdc
max. 13 mm/
max. 10 mm/
sec.
sec.
120 W
–
–
1500 N/750 N
3000 N/750 N
37