7.13 Exchanging the primary fuse
The primary fuses are in a fuse box under the mains connection.
•
Isolate the lifting column from the mains.
•
Press the retaining clip 2 together and pull the
container 1 out of the lifting column.
•
Replace the defective fuses 3 with new fuses of the
same type (the value of the fuses can be obtained on
the device sticker).
•
Push the container back into the lifting column until
it engages securely.
Using unsuitable fuses or repairing fuses can cause a fire, lead to injuries and accidents,
and damage the lifting column.
•
Always isolate the lifting column from the mains before you change a
fuse.
•
Never repair a fuse.
•
Always replace a fuse with a new fuse of the same rating and the same
size.
•
Never replace a fuse with a metal strip, a paper clip or anything similar -
not even for a short time!
Do not continue to operate the lifting column if the fault cannot be rectified by ex-
changing the primary fuse. Contact Rose+Krieger!