Bezzera VERTICALE Manual De Instrucciones página 35

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
Problem
The flow of coffee is excessive
The coffee supplied is too cold
The coffee supplied is warm
The coffee supplied is too hot
Diagnostics/Solution
The coffee is supplied too
quickly and the cream is lighter
than usual.
Possible causes:
1 – The grinding of coffee is too
coarse.
2 – The coffee in the filter hold-
er has not been pressed
enough.
3 – The dose in the filter holder
is scarce.
4 – The pressure supplied by the
pump is high (> 10 bar – 1
MPa).
Possible causes:
1 – The cups are cold.
2 – The filter holders are cold.
3 – The grinding of the coffee is
too thin.
4 – The machine's water circuit
is dirty (limestone).
5 – The boiler's pressure is low-
er than 0.8 bar (0.08 MPa).
The coffee supplied is warm if
the pressure is normal, between
1 and 1.2 bar (0.1 – 0.12 MPa).
In this case, the pressure value
is not correct.
Possible causes:
1 – The boiler's pressure is
higher than 1.3 bar (0.13
MPa).
2 – The machine is covered by
something
that
cooling.
3 – The machine was installed
in a position that does not
allow air circulation
35
MOD. BEZZERA VERTICALE
In cases 1-2-3 adjust grinding
and/or dosing of coffee.
In the 4th case, a technician
must be consulted.
In the 1st case, use the cup
warmers.
In the 2nd case, keep the fil-
ter holder assembled on the
group.
In the 3rd case, adjust the grind-
ing of the coffee.
In cases 4-5, call a specialized
technician.
Call a specialized technician to
check the exhaust valve. Mean-
while, to use the machine, open
the steam tap (Fig. 01; pos. 9);
the boiler's pressure will drop to
zero, thus causing the enabling
of the resistor and the increase
of temperature. Perform this op-
eration daily when turning on
the machine.
In the 1st case, call a special-
ized technician.
In cases 2-3 reset the machine's
cooling conditions.
prevents
Advices

Publicidad

Tabla de contenido
loading

Tabla de contenido