Congratulations on your purchase
Congratulations on purchasing the latest energy-efficient ceiling fan technology. This fan uses (AC) alternating current,
allowing for very high energy efficiency and high air circulation volume without added noise.
Operation options: Your (AC) motor is the latest in fan design technology. It can be controlled via a wall panel, manually using
a pull chain or using a remote control (depending on the model).
Caution
Follow these instructions carefully to enjoy maximum safety in the installation and operation of this
equipment.
The minimum distance between the lamp and any illuminated objects must be greater than 1m.
The electrical installation of the ceiling fan must be carried out by an authorized electrician in order
to be covered by our warranty.
This device can be used by children aged 8 years and above and people with reduced physical,
sensory or mental abilities or lack of experience or knowledge, if they have been given appropriate
supervision or training regarding the use of the device and they understand the dangers of its use.
<8
Children should not play with the device. The cleaning and maintenance of the device should not be
carried out by children without supervision.
The fan must be installed in such a way that the blades are more than 2,3m above the ground. Make
min 0,3m
sure that there is a space of at least 30cm between the fan's blades and any wall or other obstacle
that they could hit. It is important to note that the greater the distance, the more efficient the air flow
min 2,3m
produced will be.
Before contacting the technical service, it is recommended to read the troubleshooting guide inclu-
¿?
FAQ
ded in this manual.
Safety precautions
The information contained in the following pages has been prepared to ensure your maximum enjoyment of your fan:
1. The installation must be carried out by qualified personnel to do electrical installations in accordance with the regulations
in force in the country of installation.
2. Any action performed for the electrical connection of the device, such as its cleaning, must be carried out after ensurin
that the general power supply is disconnected, by removing the corresponding fuse or disarming the protective switch in
order to ensure total isolation of the power supply.
3. The fan must be installed at a location on the ceiling sch that the blades are at least 2.3 m above the floor and 300 mm
from any object or wall. The mounting bracket must be attached to a ceiling structure that is capable of supporting a
minimum of 30 kg using the two screws provided. At least 30 mm of the length of the screws must be screwed into the
bracket. When deciding where to mount the fan, be sure that there is at least 30 cm of space between the fan and any
wall or other obstruction that the fan blades could collide with. The greater this distance, the more effective the air flow
produced.After the fan is mounted, be sure that the blades are no less than 2.3 m above the ground
4. The ground wire of the fan must be connected to the earth network of the installation, to avoid any derivation that may
put people in danger.
5. Do not connect the fan's power supply to any dimmers, potentiometers, or light switches, as it will cause the fan to mal-
function and/or will damage the motor. For the electrical connection it is necessary to incorporate a switch disconnector
in accordance with the installation regulations, which ensures an omnipolar cut, directly connected to the power termi-
nals and must have a contact separation at all its poles, which provides total disconnection under conditions of Category
III overvoltage. The fan must be directly connected to a properly protected installation circuit (magnetothermal differential
switch with the adequate size for the fan's consumption and technical specifications). Only use the fan's control to turn
it on or stop it.
6. It is recommended to not use these types of fans along with gas installations simultaneously in the same room.
7. The fan must be not be moving and must have come to a complete stop before changing its direction of rotation. This will
prevent damage to its motor and to the control unit, when applicable.
8. Do not insert anything that could hit the fan's blades into its pathway while it is moving, as this could cause damage to
people, can damage the blades, and can offset the balance of the unit, causing vibrations and wobbling.
9. After installing the fan, ensure that all fastenings are secure and tightened in order to avoid any noise caused by loose
elements.
10. Due to the fan's movement, certain fastenings may become loose. Check all fastenings twice per year at a minimum in
order to ensure that they are sufficiently tight. If necessary, they must be retightened.
9