6
Tank Solutions:
UC30
General Purpose Cleaning Solution
Concentrate in MeterDose
Dispensing Bottle (16 oz.)
UC32
Enzymatic Ultrasonic Cleaner
Concentrate in MeterDose
Dispensing Bottle (8 oz.)
UC34
Plaster & Stone Remover
Powder Concentrate in
Jar (1.85 lbs.)
UC38
Germicidal Ultrasonic Cleaning
Concentrate in MeterDose
Dispensing Bottle (8 oz.)
UC39
Cement Remover Concentrate
in MeterDose Dispensing
Bottle (16 oz.)
UC42
Germicidal Ultrasonic Cleaning
Concentrate in MeterDose
Dispensing Bottle (16 oz.)
XIII. Maintenance
A. Cleaning
All components should be cleaned
each day by wiping with a soft cloth
moistened with a commercially
available mineral deposit remover
followed by cleaning with isopropyl
alcohol or a mild disinfectant.
CAUTION: Do not use petroleum
based solvents, iodophors or phenolic
based products. (Iodophors and
phenolics can stain the surface of the
unit.) Clean up all liquid spills
immediately. Rust deposits on tank can
be cleaned/removed with a commercially
available stainless steel cleaner.
B. Inspecting the Power Cord
Periodically check the power cord for
damage and see that the connectors
at both ends of the cord are fully
seated.
C. Changing the Fuse
1. Remove the power cord from the
wall outlet first and then from the
power cord receptacle on the rear of
the unit.
2. The fuse compartment is located
directly next to the power cord
receptacle. To access, take a small,
flat-headed screwdriver to the tab on
the fuse holder. Apply slight pressure
to release the fuse holder (Fig. 12).
3. Gently remove the fuse from the
fuse holder.
4. Examine the fuse (Fig. 13). If blown,
replace with a fuse that matches the
unit's voltage and current (see
®
section XIV). If fuse appears to be in
473 ml
good condition return the unit to your
dealer or Coltène/Whaledent.
236 ml
5. Plug the power cord into the power
cord receptacle on the rear of the
unit. Then plug the power cord into
840 g
the wall receptacle.
XIV. Unit Specifications
236 ml
Transducers: 2
473 ml
UC125H unit
100 [100V 50/60 Hz, 137W (max.)]
473 ml
115 [115V 50/60 Hz, 137W (max.)]
230CE [230V 50/60 Hz, 137W (max.)]
230UK [230V 50/60 Hz, 137W (max.)]
240 [240V 50/60 Hz, 137W (max.)]
NOTE: Heated units: 345 watts max.
Operating
Frequency:
Tank Capacity:
Use Capacity:
Overall Dimensions:
Tank Dimensions:
Fuse Type:
Time Lag:
100-115V Heated units
230-240V Heated units
EMC: Class A
IEC 60417-5041
Caution, Hot Surface
!
ISO 3864, No B.3.
Caution: Refer to accompanying
documents
ISO 3864, No B.3.6
Caution: Risk of electric shock
XV. Warranty Information
BioSonic Ultrasonic Cleaners are
manufactured to impeccable standards
and have been developed specifically for
use in dentistry and are intended to be
operated only by dental professionals in
accordance with the instructions
contained in this guide. However,
notwithstanding anything contained
herein, the user shall at all times be
solely responsible for determining the
suitability of the product for the intended
purpose and the method of its use. Any
guidance on application technology
offered by or on behalf of the
manufacturer, whether written, verbal or
by demonstration, shall not relieve the
dental professional of his/her obligation
to control the product and to make all
professional judgments regarding its use.
Coltène/Whaledent products are
manufactured from new parts or new
and serviceable used parts. Regardless,
our warranty terms apply. The products
are guaranteed in accordance with the
terms of the written Certificate of Limited
55 kHz
Warranty.
1.25 gallon or 4.75 L
Coltène/Whaledent Inc. provides no
warranties or guarantees covering this
1 gallon or 3.78 L
product, expressed or implied, including,
16.5 x 10.5 x 13.8 in.
without limitation, any warranties as to
42 X 27 X 35 cm
merchantability or fitness for use.
Coltène/Whaledent Inc. assumes no
11.25 x 5.62 x 5 in.
responsibility for any inconvenience,
28.6 x 14.3 x 12.7 cm
loss, injury, or direct, indirect, or
5 x 20 mm Cartridge
consequential damage arising from the
IEC 60127-2 Sheet 3
possession or use of the product.
4 Amp
Tampering with any of the components,
2.5 Amp
misuse, negligence, alteration, water
damage, accident, or lack of reasonable
or proper maintenance and care will void
the warranty. Any claim for damage or
breakage in transit should be made at
once against the carrier. If factory service
is required, be certain to properly pack
your equipment and return prepaid and
insured to the factory. Please refer to the
Certificate of Limited Warranty for
warranty terms and conditions.
®