Holding a button down while turning the Meter on activates a power-up option. Power-up options allow you to use additional
features and functions of the Meter. To select a power-up option, hold down the appropriate button indicated while turning the
Meter from OFF to any switch position. Power-up options are cancelled when the Meter is turned Off.
Disables automatic power-off function Display shows PoFF until the button is released
SELECT
Disable Beep function
ENTER
The Meter have automatic power off function (Sleep mode) to conserve battery power. if there is no function change or button
press for 10 minutes. The Meter comes out of Sleep mode when a key is pressed or when the rotary switched is changed.
To disable the Sleep mode, hold down SELECT button while turning the Meter on. Sleep mode is always disabled in the
insulation test mode, or if the auto power off feature has been disabled by pressing SELECT button when the Meter is turned
on.
Press Hold button to freeze the displayed value. Press again to release the display.
Show the difference between actual value and the relative base.
Press REL Button to enter relative measurement and the meter will record the initial value when pressing the key.
Displayed value = Actual value -Initial value
Press REL Button again to exit relative measurement.
Press SELECT button to view Initial value, when the Initial value is invalid, display----.
11
In insulation test mode, press Test button to perform insulation test until the button is released. when the button is released,
the screen display hold sign.
Press Lock Button, then the screen display Lock sign, press Test Button, the meter will perform insulation test unitl you press
Test button again; The test lock will unlocked while to cancel insulation test.
Lock function is invalid when timer function is selected.
Press MEMO button, the meter enter Hold status automatically. LCD screen display 'MEMO' and the memory code on
secondary display (see below). Press △/▽ button to change the code, press enter to save the data in the preferred memory
code and the screen display 'SAVE'. The data is stroed successfully when the buzz beeps. The meter can save 20 datas and
memory code from 00 to 19.
Press READ button to display the data in memory. Press △/▽ button to change the code and read the data accordingly.
12