KPS CAT III Manual De Instrucciones página 20

Medidor de aislamiento digital hasta 1kv
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

In READ mode, press ENTER, meter display dEL n, press enter button again to delete selected data; press READ button to
delete all data. The meter will beep once the data is deleted. Press other button to quit the current satus.
When compare function is selected, the meter beeps and won't display 'PASS', when the measuring data higher than upper
limited value or lower than lower limited value.
Press COMP button will active compare function, meter display 'COMP', when the preset upper limited value is lower than
the lower limited value, COMP function is invalid, meter display '----'.
Press COMP button to view the upper and the lower limited value. The meter display 'COMP' and display 'HI' or 'LO' on
secondary screen, as below: When the meter is displaying the upper limited value or the lower limited value,press ENTER to
adjust the value. The meter will be flashing with the upper limited value or the lower limited value. Switch to the proper range
or signal polar by pressing SELECT, Press △/▽ to change the value, and press ENTER to save the value.
13
The timer function can only be activated in the insulation test. Enable the TIMER function by pressing TIMER (the meter
display TIMER), the lock function will be invalid, and the meter starts the insulation test when pressing the measure button.
When the time is due, the test is stopped.
In timer mode, the display will be as following. The current voltage and time is shown on the secondary display. The meter
just display the test voltage when it is under the insulation test, to check the time, please press △ button.
Press SELECT to check the preset time. The LCD screen display TIMER, PRES is shown on primary display, the secondary
display shows the preset time. Press ENTER, the meter display Set. The time can be adjusted by △/▽ button.
Presws ENTER again to confirm the adjustment.
14

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Cat iv

Tabla de contenido