Annex 4: Table of Vibration levels.
Mounting
Fan
Balance
category
grade
Rigid
BV-3
G 6.3
Flexible
Notes:
All vibration levels - Velocity mm/s rms.
Refer ISO 14694:2003
The values defined are at source and not intended to serve as accept / fail values. Any acceptance values and their location should be
defined between the machine manufacturer and client. The values offer guidance for possible deterioration, to identify early and avoid
major failure or potential issues and hence maintain safe operation.
Annex 5: Typical fan assemblies:-
A5.1
TGT, THGT, TGT ATEX, Short case
A5.2
TGT, THGT Long case
A5.3
TGT, THGT, TGT ATEX, Long case Access door
Manufacture
Workshop
Start up
mm/s
mm/s
rms
rms
2.8
4.5
3.5
6.3
37
In situ
Alarm
Shutdown
mm/s
mm/s
rms
rms
7.1
9
11.8
12.5