The expansion piston of the expander pistol travels automatically forwards and subsequently
back again until the set pressure has been reached.
Please pay attention to the correct expander head size! The expander head size
must match the pipe which is to be expanded!
Note: The phase time should not be less than 1 minute.
3.5
Taking out of service
Take the foot from the safety foot-operated switch and / or the hand from the microswitch.
Turn the switch (4) to OFF, disconnect the power cable and remove the connections (1, 2,
11).
Keep the devices in a safe place!
4
Electrical wiring diagram
5
Care and Maintenance
Check the oil level after approx. 300 operating hours: unscrew the air filter (A) from the pump
housing and check the oil level on the dipstick.
Always top the oil up through a funnel. Do not fill above the mark!
An oil change should be carried out every 1500 operating hours! Only use the ROTHENBER-
GER special hydraulic fluid prod. no. 58185 for this purpose.
All tube fittings are to be retightened after the first 500 operating hours!
6
Accessories
Accessory Name
Hydraulic System complete, without heads
Hydraulic Tool H 600
Foot pedal H 600 with 3 m cable
Electro-Hydraulic Expander Pistol H 1
Adjusting tool for H 1
S-Head adaptor for H 1
Electro-Hydraulic Expander Pistol H 2
Adjusting tool for H 2
ROTHENBERGER Part Number
13100
13002
12013
12001
12017
11007
12002
12018
ENGLISH
15