9.2.FLOAT SWITCH SETTING
By lengthening or shortening the stretch of cable between the float and the fixed point (Float
locking) it is possible to regulate the level at which the pump switches off. Ensure that the float
switch can move freely when the pump is operating.
Make sure the stop level does not uncover the filter.
Viginox MXO
Float locking
wire
10 PRECAUTIONS
•The suction filter must always be present when pump is operating.
•The pump must not be started more than 30 time in one hour so as not to subject the motor to ex
cessive thermal stress.
•DANGER OF FROST: When the pump remains inactive at temperatures of less than 0°C, it is
necessary to ensure that there is no water residue which might freeze, and cause cracking of the
pump components.
• If the pump has been used with substances that tend to deposit, rinse it after use with a powerful
jet of water so as to avoid the formation of deposits or scale which would, tend to reduce
the pump characteristics.

11 MAINTENANCE AND CLEANING

In normal operation the pump does not require any type of maintenance, thanks to the oil bath
lubricated seal and to the greased-for-life bearings.
The electropump can only be dismantled by skilled and qualified personnel, in possession
of the technical qualifications required by the specific regulations in force.
Viginox/Viginox V
Float locking
wire
22
In any case, all repair and maintenance jobs must be carried out only after having disconnected
the pump from the power mains, once made sure that it cannot suddenly begin working.During
dismantling it is necessary to pay great attention to sharp parts which may cause injury.The cutting
edge flange of the electropump is provided of aspiration fans. It is advisable, every now and then,
to clean these fans to avoid a loss of efficiency. Best cleaning is obtained through a throw of water.
Sand and other abrasive materials cause precocious wear and tear, as well as loss of performances.

12 MODIFICATIONS AND SPARE PARTS

Any modification not authorized beforehand relieves the manufacturer of all responsibility.
All the spare parts used in repairs must be original ESPA. For codes and denominations see
enclosed sheet.
All accessories must be approved by the manufacturer so as to be able to ensure maximum
safety of the machines and systems in which they may be fitted.
13 TROUBLESHOOTING
FAULT
CHECK (possible cause)
A.Make sure motor is live and
1.The motor does not
check that the mains voltage
start and makes no
corresponds to the one on the
noise.
data plate.
B.Check the protection fuses.
C.The float switch prevents
start up.
D.The shaft is not turning.
A.The suction filter or the pipes
are obstructed.
2.The pump does not
deliver.
B.The impellers are worn or blo-
cked.
C.The check valve, if installed on
the delivery pipe, is blocked in
closed position.
D.The fluid level is too low.On
starting, the water level must
be higher than the filter level.
E.The head required is higher
than the pump's characteristics
3.The pump does not
A. The float does not interrupt
stop.
the operating of the pump.
REMEDY
B. If they are burnt-out, change
them.
C. Make sure float moves freely and
check its efficiency.
D. Turn the shaft as indicated in
the Warnings chapter
(Paragraph 6.3. ).
A.Remove the obstructions, as
indicated in the Warnings
chapter (Paragraph 6.4).
B.Change the impellers or remove
the obstruction.
C. Check good operation of the
valve and replace it if necessary.
D.Regulate the length of the
float switch cable (See chap
ter on Warnings - Paragraph
9.2.)
A. Make sure float moves freely
and check its efficiency.
23