FAULT
CHECK (Possible cause)
4.The flow rate is
A .Ensure that the suction filter is
insufficient.
not partly blocked.
B. Ensure that the impellers or the
delivery pipe are not partly
blocked or fouled with scale.
C. Ensure that the impellers are not
worn.
D. Ensure that the check valve (if
fitted) is not partly clogged.
E. Check the direction of rotation
in three-phase versions (See
Chapter on Electrical connection
- Paragraph 8.4.).
5.The overload protec
tion device stops the
A.Ensure that the fluid to be
pump.
pumped is not too dense
because it would cause
overheating of the motor
B.Ensure that water temperature
is not too high (see liquid tem-
perature range).
C.The pump is partly blocked by
impurities.
D.The pump is mechanically
blocked.
DON'T DISPOSE OF WORN-OUTS UNITS THROUGH THE
HOUSEHOLD GARBAGE
The appliance, its packaging and accessories are all produced from
recyclable materials and must be disposed of accordingly, in the suita-
ble dispose places, adhering itself to the modalities previewed from the
enforced norms in matter
REMEDY
A.Remove any obstructions, as
indicated in the chapter on
Warnings (Paragraph 6.4.).
B. Check good operation of the
valve and replace it if necessary.
C.Change the impellers
D. Accurately clean the
check valve.
E. Invert two wires in the
power cable.
B Reduce liquid temperature.
Wait until thermal protection
switch resets, about 20 mins.
C. Accurately clean the pump.
D.Check for the occurrence of
rubbing between moving and
fixed parts; check the state of
wear of the bearings (contact
the supplier).
24
14 TECHNICAL DATA
TECHNICAL DATA
Viginox MXO 30
220-230 V/50 Hz
Electric connection/voltage (Hz)
Power rating P1 (Kw)
Current absorption (A)
Max. High head pressure (mt)
Max. capacity (I/min)
Max temperature of liquid (°C)
Horizontal suction. (mm)
Max. submersion depth (mt)
N° of impellers
Electric cable (mt)
Foreign bodies aspir. up to ø... (mm)
Discharge connection thread DNM
Pump dimension BxD (mm)
Packing dimension LxMxN(mm)
Weight (Kg)
-The characteristics and technical data are not binding. ESPA reserves the right to make modifications without notice. There-
fore weights, dimensions,performances and any other stated issues are indicative only and not binding
Viginox MXO 60
220-230 V/50 Hz
---
380-400 V/50 Hz
0,5
0,7
---
0,7
1.8
3
---
1,4
7
10
150
175
50
50
60
60
5
5
1
1
5-10
5-10
10
10
1
1
1 / 4"
1 / 4"
154 x 234
154 x 234
220 x 190 x 280
220 x 190 x 280
5,5
6,2
25