Technical Data - salmson LRE Serie Manual De Instalación Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

5.2

Technical data

Property
Speed range
Nominal diameters DN
Pipe connections
Permissible min./max. fluid temperature
Ambient temperature min./max.
Maximum permissible operating pressure
Insulation class
Protection class
Electromagnetic compatibility
Emitted interference in acc. with
Interference resistance in acc. with
Sound pressure level
Approved fluids
Electrical connection
PTC thermistor
Speed control
Relative humidity
Fluids
Installation and operating instructions LRE-JRE
Value
750-2900 rpm
32; 40; 50; 65; 80
Flanges PN 16
-20 °C à +120 °C
0 to 40 °C
10 bar
F
IP 55
EN 61800-3
EN 61800-3
< 71 dB(A)
Heating water in acc. with VDI 2035
Cooling/cold water
Water/glycol mixture up to 40 % vol.
Heat transfer oil
Other fluids
3~400 V ± 10 %, 50 Hz
3~380 V -5 % + 10 %, 60 Hz
Built-in full motor protection (PTC)
Built-in frequency converter
< 95 %, without condensation
When ordering spare parts, make sure to state all the information
given on the pump and motor name plates.
If water/glycol mixtures are used (or fluids with a viscosity other than
that of pure water), an increase in power consumption of the pump is
to be taken into account. Only use mixtures with corrosion inhibitors.
The respective manufacturer's instructions are to be observed.
• The fluid must be sediment-free.
• Salmson's approval must be obtained for the use of other fluids.
• Mixtures with a proportion of glycol of > 10 % influence the Δp-v
pump curve and the flow calculation.
NOTE
The flow value shown on the IR-PDA Module display or output to the
building management system must not be used to control the pump.
This value is merely an indicator of general trends.
A flow value is not output on every type of pump.
NOTE
Always read and follow the material safety data sheet for the fluid
being pumped!
• Pump LRE/JRE
• Installation and operating instructions
English
Remarks
EN 1092-2
Residential
Industrial
Standard version
Standard version
Standard version
Only for special version
Only for special version
Supported network types:
TN, TT
54

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Jre serie