8. CALIBRATION
Turn on the scale. Keep pressed
Pn
Display will show "
" briefly PIN is activated. Press the PIN number to get into the parameter menu.
•
The default PIN number is "0000"
•
Press numeric key 0 four times, display will be shown Pn - - - -
•
Press
key to confirm, it will enter into the parameter settings and will to show "
16
The scale RS232 protocol will be determined by the Baud & Pr settings
oFF
Cont
StC
toLE do
Cr
nC iE
En
nC iG
tEC
EASY
ModE
tpv0
7PV 2A
7PV 2b
7PV 4
7PV 7
7EdC 1
tisa A
tisa B
tisa v
bAUd
1200 - 2400 - 4800 - 9600 - 9200 - 38 400 - 115200
8n 1
Pr
7E1
7o1
Comman
Model
Manual
key during the self test.
RS232 function disable
Continues data transmission
Stable data transmission (sending continue frame)
Protocol type 1: Toledo
Protocol type 2: NCI-ECR
Protocol type 3: NCI-General
Protocol type 4: TEC
Protocol type 5: Easy Weigh
7PV-a
trace
7PV-b
Protocol type 7 : TPV 2A
Protocol type 8 : TPV 2B
Protocol type 9 : TPV 4
Protocol type 10 : TPV 7
Protocol type 11 : TED C1
Protocol type 12: TISA A
Protocol type 13 : TISA B
Protocol type 14 : BD TISA
8 data bits, no verify, 1 stop bit
7 data bits, Even verify, 1 stop bit
7 data bits, Odd verify, 1 stop bit
Activate comman mode
Activate manual mode
USER MANUAL XTA
Manual
Command
Contin
Protocol type 6 : TPV0
Manual
Command
Contin
Transmission speed
F0 CAL
".
EN