Descargar Imprimir esta página

Simer A5500 Manual Del Usuario página 10

Systema de respaldo de la batería

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
TABLE IV - 8 Amp Charger Light Indications
Charger Light
On/Off/Flashing
All LEDs
Flash ONCE
AC Power
On
Status
Very Slow Flash
Pump Run
Fast Flash (2x/second)
Status
Slow Flash (1x/2 seconds)
Off
Alarm Silence
On
Off
Battery Status
On
Slow Flash
Fast Flash
Off
Charger Mode
Slow YELLOW Flash
Solid YELLOW
Fast YELLOW Flash
Solid GREEN
Flashing alternately
YELLOW/GREEN
TABLE V - 8 Amp Charger Audio Alarm Indications
Audio Alarm
Mode
On - Beeping
Slow Beep in Synch with
'Battery Status' LED
On - Beeping
Fast Beep in Synch with
'Battery Status' LED
On - Beeping
Fast Beep in Synch with one or more
of the 'AC Power', 'Pump Run', or
'Alarm Silence' LEDs and with the
'Charger Mode' LED flashing alternately
YELLOW/GREEN
On - Beeping
Fast Beep in Synch with
'Pump Run Status' LED
For parts or assistance, call Simer Customer Service at
Alarm Buzzer
Off
Connected system to AC power or to battery; or, pressed
'Reset' when in ERROR mode
Off
System is receiving AC power
Off
System is not receiving AC power
Beep in synch
Pump is running. Press LEFT side of rocker
with LED flash
switch to silence alarm
Off
Pump has run, but is not running now
Off
Pump has not run
Alarm is silenced
Alarm is active
Off
System is not connected to a battery or is connected to a
battery charged to less than 1 volt DC
On
Battery voltage less than 10.9 volts. Alarm
can be silenced
On
Battery voltage is less than 8.2 volts Alarm
CANNOT be silenced
Off
System is properly connected to a battery
Off
System is in the "pre-qualification" stage. This will last
from 1 minute to 5 hours, depending on the condition
of your battery
Off
System is in the "Constant Current Charge" stage. This
will continue until the battery voltage reaches
approximately 14.3 volts
Off
System is in the "Constant Voltage Charge stage". This
could last up to 14.5 hours
Off
Battery is fully charged
On - Beeping
System is in an ERROR mode. Alarm will beep in synch
with one or more of the 'AC Power Status', 'Pump Run',
or 'Alarm Silence' LEDs. See Tables II and III, Page 9,
for more information
Indicates
Battery is
down to about
10.9 Volts
Battery is
down to about
8.2 Volts
System is
in ERROR
mode
Pump is
running
1-800-468-7867 / 1-800-546-7867
Indicates
Action
Investigate cause; battery is very low. You
have limited pump run time left. Press
and release LEFT side of toggle switch to
silence alarm
Investigate cause; battery is nearly dead.
You have almost no pump run time left.
Alarm CANNOT be silenced
Refer to ERROR Mode Charts, Page 9 for
more information
None. Alarm will stop when pump stops
running. To silence alarm, press and release
LEFT side of toggle switch
10

Publicidad

loading