Installation
1. Connect charger as shown in Table I and Figure 8.
PUMP/POMPE BOMBA (+)
FLOAT/FLOTTEUR/FLOTADOR (+)
PUMP POMPE BOMBA ( )
BATTERY/BATTER E/BATERÍA ( )
FLOAT/FLOTTEUR/FLOTADOR ( )
BATTERY/BATTER E BATERÍA (+)
PUMP/POMPE/BOMBA (+)
FLOAT/FLOTTEUR/FLOTADOR (+)
PUMP/POMPE/BOMBA (–)
BATTERY/BATTERIE/BATERÍA (–)
FLOAT/FLOTTEUR/FLOTADOR (–)
BATTERY/BATTERIE/BATERÍA (+)
Figure 8 – Wiring Connections A5500
TABLE I - A5500 Wiring Connections
Connect the
Positive (+) lead from the battery
Negative (–) lead from the battery
Positive (+) "Backup sump Pump"
lead (BROWN wire)
Negative (–) "Backup sump Pump"
lead (BLACK wire)
Positive (+) Float switch Lead
(WHITE wire)
Negative (–) Float Switch Lead
(BLACK wire)
2. Plug the charger into a 115 Volt AC outlet delivering
at least 15 amps. Do not use a switch controlled
outlet. Mark the circuit in the main power panel
"Backup sump pump power supply; do not turn off".
3. With the charger properly connected and plugged in,
the panel on the front of the charger will show one or
more of the following conditions (See Figure 9).
For parts or assistance, call Simer Customer Service at
To the position indicated
below, on the charger
Positive battery terminal
(leads are provided)
Negative battery terminal
(leads are provided)
Positive pump lead terminal
Negative pump lead terminal
Positive float switch terminal
Negative float switch terminal
A.C.POWER
STATUS
PUMP RUN
STATUS
ALARM SILENCE
BATTERY STATUS
CHARGER MODE
SILENCE
ARRÉT/SILENCIO
Figure 9 – A5500 LED Panel
Red "AC Power Status" LED - AC power is present
Yellow (bicolor) LED on continuously - Prequalification test is com-
plete and charging is in process
Yellow "Charging" LED flashing on and off quickly - Equalization
charge stage
Green (bicolor) LED is on - Battery is being maintained at full
charge
Bicolor LED flashing yellow/green alternatively - See Error
Charge Table (Table II, Page 9)
Test the Assembly:
1. Plug the primary pump into a properly grounded
3-prong outlet.
2. Fill the sump with water to start the primary pump.
Check for leaks.
3. Unplug the primary pump and fill the sump with
water to start the backup system pump. Check for
leaks.
4. Plug the primary pump back into a properly grounded
3-prong outlet. The system is now ready for operation.
1-800-468-7867 / 1-800-546-7867
ÉTAT DU COURANT ALTERNATIF.
ESTADO DE LA CORRIENTE ALTERNA.
ÉTAT DE FONCTIONNEMENT DE
LA POMPE.
ESTADO DE FUNCIONAMIENTO DE
LA BOMBA.
ARRÉT D'ALARME.
SILENCIO DE ALARMA.
ÉTAT DE LA BATTERIE.
ESTADO DE LA BATERÍA.
MODE DU CHARGEUR.
MODO DE CARGADO.
ALARM
RESET/RÉARMEMENT
ALARME/ALARMA
REPOSICIÓN
3464 0799
8