Operating Instructions SATAjet 1000 B (RP/HVLP)
Malfunction
Corrosion on air
cap thread, material
passages (cup con-
nection) or spray gun
body.
Material leaks from
behind the paint nee-
dle seal.
Spray gun drips at flu-
id tip ("fluid tip cone").
11. Disposal
Dispose of the completely emptied spray gun as a recyclable material.
To avoid damage to the environment, dispose of the spray material and
release agent separately from the spray gun in an appropriate manner.
Comply with local regulations!
12. After Sale Service
Accessories, spare parts and technical support may be obtained from
your SATA dealer.
13. Accessories
Art. No.
Description
3988
Paint strainer
6981
Quick coupling nipple G ¼ " (female thread)
27771
Air micrometer 0 – 845 with pressure gauge
64030
SATA cleaning set
53090
Air hose
Cause
Cleaning solution (wa-
tery) remains in the
gun for too long.
Unsuitable cleaning
solutions used.
Paint needle seal de-
fective or missing.
Paint needle dam-
aged.
Paint needle clogged.
Contamination be-
tween paint needle tip
and fluid tip.
Damaged nozzle set.
Corrective action
Have gun body re-
placed. Heed cleaning
instructions (see chap-
ter 9).
Replace paint needle
seal (see chapter 8.3).
Replace nozzle set (see
chapter 8.1).
Clean paint needle.
Heed cleaning instruc-
tions (see chapter 9).
Clean fluid tip and paint
needle. Heed cleaning
instructions (see chap-
ter 9).
Replace nozzle set (see
chapter 8.1).
Num-
ber
10 pcs.
5 ea.
1 ea.
1 set
1 ea.
EN
129