Maintenance

Fault
Cause
No connection via
Cable faulty
cable to radio
Cable not fitted
possible
correctly
Incorrect cable
connected
Pressure switch jams Pressure switch
soiled
Slide switch jams
Slide switch soiled
Slide switch damaged Replace slide switch.
5
Maintenance
5.1

Maintenance intervals

Work to be carried out
Check the functioning of the communication unit
32
5.2
Remedy
Replace cable.
!
Check connection
between cable and
radio. Fit cable again
if necessary.
Check connection
between cable and
communication unit.
Fit cable again if
necessary.
Use suitable cable.
Clean pressure
switch.
Dismantle and clean
i
i
slide switch.
If the full face mask is cleaned and disinfected manually, the
communication unit can remain mounted to the full face mask. It may,
however, be cleaned separately as well. It is not necessary to disinfect
the communication unit.
1. Dismantle the communication unit from the full face mask.
2. If neither the insert for the radio connection cable nor the insert for
X

Cleaning

CAUTION
Health hazard!
The undiluted agents are harmful to health if they come into
direct contact with eyes or skin. Wear goggles and protective
gloves when working with these agents.
Potential damage to component parts!
For cleaning and disinfecting only apply the described
procedures and use the specified cleaning agents and
disinfectants. Other agents and procedures, dosages and
exposure times can damage component parts.
The insert for the radio connector cable or the insert for the
Bluetooth
connection
communication unit. The plug inserted into the radio unit may
not be immersed in water.
NOTICE
The specified cleaning agents and disinfectants are not
approved in all countries. Dräger tests and recommends
different cleaning agents and disinfectants. Information on
which other cleaning agents and disinfectants can also be
used is available from Dräger.
the Bluetooth connection is mounted, plug in the dummy insert. If
can
remain
installed
on
Dräger FPS-COM 7000
the

Publicidad

Tabla de contenido
loading

Tabla de contenido