Maintenance Work - Dräger FPS-COM 7000 Instrucciones De Uso

Ocultar thumbs Ver también para FPS-COM 7000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 51
the contacts of the radio connector on the communication unit are
open, water can penetrate the communication unit and damage it.
3. If no earphone is plugged in, make sure to insert the
corresponding plug into the earphone jack.
4. Fit the protective cap onto the full face mask and clean the full face
mask in accordance with the corresponding instructions for use.
5. Clean the communication unit with lukewarm water with the addition
®
of Sekusept
Cleaner and a soft cloth (temperature: max. 30 °C,
concentration depending on the level of contamination: 0.5 - 1 %)
Tough dirt marks can be removed using a soft brush. In the process,
ensure that the loudspeakers are not touched with the brush.
6. Thoroughly rinse all parts under running water.
7. Dry all parts either at least 12 hours in the air or 30 to 60 minutes
in a drying cabinet (temperature: max. 60 °C). Keep out of direct
sunlight.
NOTICE
i
i
The actual drying time required can vary greatly depending
on climatic influences.
8. Check whether the earphones and fastening eyes are damaged.
Replace earphones and fastening eyes if damaged (see
Chapter 5.3.2 on Page 34 and 5.3.3 on Page 34).
If the fixing lugs on the visor frame are damaged, the visor frame
of the full face mask must be replaced.
5.3

Maintenance work

CAUTION
!
During assembly work the specified torques must be
observed, otherwise the communication unit could be
damaged. Use suitable tool.
®
1)
Sekusept
is a registered trademark of Ecolab Deutschland GmbH
Dräger FPS-COM 7000
5.3.1
Replacing batteries
WARNING
!
Do not replace the batteries in an explosive environment!
Otherwise there is a risk of explosion!
The batteries are part of the approved version.
CAUTION
1)
.
!
Do not open, take apart, modify or refit the batteries.
Do not insert foreign objects into the batteries.
Do not allow the batteries to be dropped, crushed, bent,
misshapen, pierced or crushed.
Do not expose the batteries to excessive heat or place
them in a microwave oven. If the batteries are once
exposed to high temperatures, the batteries must be
replaced immediately.
If a battery leaks, the fluid must not be allowed to come
into contact with the skin or eyes. If the fluid has already
come into contact with the skin or the eyes, rinse the
affected area with large quantities of water, seek medical
assistance immediately.
Never short-circuit the batteries.
Improper handling of batteries can cause fire, explosions
or other hazards.
Approved batteries
T4:
LR6, Panasonic Powerline
T3:
LR6, Industrial by Duracell
LR6, Varta Energy 4106
LR6, Procell by Duracell
Maintenance
33

Publicidad

Tabla de contenido
loading

Tabla de contenido