1) Cut-off power supply.
2) Manually release the wing, move it to approx. half-stroke and lock it again.
3) Reset power supply.
4) Send a step-by-step control signal by pressing the button or the remote control key.
5) The wing should start an opening movement. If this is not the case, invert the movement wires (25< >27)
of the motor and the limit switch wires SWO-SWC (19< >20).
6) Adjust Time, Operating Logic and Motor Power.
ENC
The sensitivity to obstacle detection of the optical sensor is adjusted in both opening and
closing phases. Adjustment should be carried out in compliance with regulations in
force.
If an obstacle is detected, the movement is stopped and reversed for about 3 sec.
PW
Motor torque is adjusted.
Adjustment should be carried out in compliance with regulations in force.
TCA
The automatic closing time can be adjusted by this trimmer.
Adjustment ranges from 1 sec minimum to 90 sec maximum.
To disable the automatic closure set the trimmer to the maximum value (+)
DIP 1 "SCA/II°ch"
DIP 2 "PRELAM."
DIP 3 "BLI"
DIP 4 "P.P. Mod"
DIP 5 "SLWDCM"
DIP 6 "SLWD"
DIP 7 "ENC"
8
TO CHECK CONNECTIONS
FUNCTION OF TRIMMERS
DIP-SWITCH FUNCTION
The operating mode of the SCA/ II°ch output to terminals 17-18 is adjusted.
Off: Output is set as SCA (open gate indicator light) or as FotoTest if DIP5 is ON.
On: Output is preset as 2
Forewarning flashing light enabled or disabled.
Off: disabled forewarning flashing light.
On: enabled forewarning flashing light. The flashing light is activated 3 sec before
the starting of the motor.
The PP input (Step-by-Step) is enabled or disabled in the opening phase.
Off: During opening, all controls are regularly carried out.
On: During opening, the PP input is disabled. Hence, also controls sent by the
control unit are disabled.
The other inputs are therefore still active.
The "P.P. push-button" and the transmitter operating modes are selected.
Off: Operation: OPEN > STOP > CLOSE > STOP >
On: Operation: OPEN > CLOSE > OPEN >
Slowdown space.
Off: Slowdown space= 35cm.
On: Slowdown space = 70 cm.
Braking is enabled or disabled.
Off: Braking is disabled.
On: Braking is enabled.
For motors equipped with optical sensor (encoder) and DIP7 only: ON. The control
unit carries out the final phase of the opening and closing movements at reduced
speed (approx. 70 cm of stroke).
"WARNING: external mechanical factors, e.g. weight and friction on the
sliding movement of the door leaf, as well as environmental factors, e.g.
temperature, and weather agents may affect the performance of braking.
Therefore, this functions requires a structure in good conditions and
adequate maintenance."
The optical sensor is enabled or disabled (Encoder).
Off: Disabled optical sensor. Detection of obstacles and braking not enabled.
On: Enabled optical sensor. Through the ENC trimmer, the sensitivity of obstacle
detection is adjusted in compliance with regulations in force.
ch (second radio channel).
nd