English
5.6 Machine Stop
1) Press the switch (fig. 1; pos. 1) and verify if the led is off.
2) Turn off the water supply tap (R version).
5.7 Dose Programming (BZ02 DE)
To program every single dose, do what follows: keep pressed the key "PROG" relative
to the continuous dose programming (fig. 2; pos. 1) for about 5 seconds until the LED
blinks.
Select the desired dose by pressing the relative key (LED switching-on), select the
key once again after reaching the desired dose (LED switching-off); the dose is
programmed.
Notes:
- The push-button panel LEDs blink intermittently: no water into the tank.
- The push-button panel LEDs blink intermittently and quickly: no water into the boiler.
- The LED of the button selected blinks: too fine coffee.
N.B.
If the water should not come out of the group (fig. 1; pos. 5) although the boiler is under
pressure and there is water into the tank, turn off the switch (fig. 1; pos. 1) and release
the vapour from the tap (fig. 1; pos. 4). Wait for the machine to cool completely.
Turn on the switch again (fig. 1; pos. 1) and press the continuous dose key until the
water comes out of the group, press stop and wait for the machine to be under
pressure.
34
BZ02PM_BZ02DE
cod.9941038
ed.02/04
rev.00