Function And Characteristics; Characteristics; Function; Available Stroke Lengths And Magnets - Balluff BTL5-A/C/E/G1-M-B/Z-DEX-K/KA Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 52
BTL5-A/C/E/G1_-M_ _ _ _-B/Z-DEX_-K_ _/KA_ _
Micropulse Linear Transducer - Rod Style
2

Function and characteristics

2.1

Characteristics

Micropulse transducers are char-
acterized by:
Very high resolution, repeatabil-
ity, and linearity
– Insensitive to shock, vibration,
contamination, and noise
Absolute output signal
Wear- and maintenance-free
measuring principle
Cable length between trans-
ducer and controller up to 20 m
Pressure rated to 350 bar when
installed in hydraulic cylinder
(zone 1)
Protected to IP 67 per IEC 60529
2.2

Function

The transducer contains a wave-
guide enclosed by an outer stain-
less steel rod. A magnet attached to
the moving member of the machine
or to the cylinder piston is moved
over the rod and its position con-
3

Installation

Ø 5 for hook-
spanner Ø 65,
tightening torque
max. 50 Nm
BTL5...DEXB-KA_ _
axial
connection
BTL5...DEXB-K_ _
radial
connection
Fig. 3-1: BTL5...B/Z..., transducer dimensions
4
english
stantly updated. The magnet ring
must remain within the measuring
range.
The magnet defines the measured
position on the waveguide. An
internally generated INIT pulse
interacts with the magnetic field of
the magnet to generate a magneto-
strictive torsional wave in the
waveguide which propagates at
ultrasonic speed.
The torsional wave arriving at the
end of the waveguide is absorbed in
the damping zone. The wave arriv-
ing at the beginning of the wave-
guide creates an electrical signal in
the coil surrounding the waveguide.
The wave propagation time is used
to derive the position. Depending on
the version the corresponding value
is output as a voltage or a current
either with rising or falling character-
istic. This takes place with high
precision and repeatability within
the measuring range indicated as
the nominal stroke length.
B: 30-1
nom. length =
Z: 2"-0.04"
measuring range
O-ring Viton
GFLT 90
magnet ring
mounting surface
nom. length =
B: 30-1
measuring range
Z: 2"-0.04"
O-ring Viton
GFLT 90
thread size:
B: M18×1.5
Z: 3/4"-16UNF
Flameproof enclosure
The electrical connection between
the transducer, the processor/con-
troller and the power supply is via
a fixed cable, which is either axi-
ally or radially connected.
Dimensions for installing the
Micropulse transducer: ➥ ➥ ➥ ➥ ➥ Fig. 3-1
Dimensions for installing the mag-
net: ➥ ➥ ➥ ➥ ➥ Fig. 3-5
Dimensions for installing the float:
➥ ➥ ➥ ➥ ➥ Figs. 3-7 to 3-10
2.3
Available stroke lengths
and magnets
To ensure flexible application, nomi-
nal transducer stroke lengths of
from 25 to 4000 mm and various
types of magnets are available.
Magnets/floats therefore need to be
ordered separately.
unusuable area
not included
thread
M4 × 4/
6 deep
float
float stop
BTL5...DEXA-KA_ _
damping zone
thread
M4 × 4/
6 deep
float stop
BTL5...DEXA-K_ _
Ignition Class "d"

Publicidad

Tabla de contenido
loading