TROUBLESHOOTING
The appliance has been tested be fore being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and ma lfunctions which might occur dur ing
use.
The user can solve some of these problems him-
self, but for others specific technical kn owledge or
skill is re quired, and so they must only be carr ied
Faults
Smell of gas.
The pilot light does not ignite.
The pilot light goes out.
The flame is yellow.
Burner control knob is stiff.
FAULT
out by qualified staff with recognised experience ac-
quired in the specific sector of operation.
For all requirements contact the agents or
the headquarters of Angelo Po which can
be found in the contacts section of the web-
site http://www.angelopo.com.
Causes
Occasional leak because flame
has gone out.
The spark ignition devices are not
working.
Air in pipelines due to long period
out of use.
The thermocouple has not
warmed up enough.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Gas control valve malfunction.
- 15 -
Important
Remedies
Turn off the gas supply tap and
ventilate the room.
Check that the ignition devices
are in good working order
Light by hand with a naked
light.
Important
Contact the after-sales
service.
Make more attempts
to light the flame.
Make more attempts
to light the flame.
Important
Contact the after-sales
service.
Important
Contact the after-sales
service.