To carry out this operation, proceed as follows.
Turn off the gas supply tap .
1)
Pull off the knob (A).
2)
Take out the screws C) and take down the dash-
3)
board (B).
Unscrew the union (D).
4)
Remove the nozzle(E) and replace it with the
5)
one suitable for the type of gas in use (see table
at back of manual).
Retighten the union (D).
6)
Replace the control panel (B) and the knob (A)
7)
on completion of the operation.
EQUIPMENT DECOMMISSIONING, DEMOLITION AND DISPOSAL
When decommissioning the appliance, a series
of procedures must be carried out to ensure that
the appliance and its components are not a hin-
GB
drance and are not easily accessible.
To ensure that the appliance cannot constitute
hazards for people or the environment, all en-
ergy sources (electricity, etc.) must be discon-
nected and rendered unusable, and any liquids
present must be drained (lubricants, fl uids, etc.).
Place the appliance in a suitable area which is not
easily accessible, with barriers to prevent anyone
from accessing it.
When scrapping, sort all components by chemi-
cal characteristics and dispose of them separate-
ly in accordance with the relevant legal require-
ments.
3269771_inst_GB
REPLACING THE BURNER PILOT LIGHT NOZZLE
A
B
Important
Do not dump non-biodegradable products,
lubricating oils, and non-metallic compo-
nents (rubber, PVC, resins, etc.) in the envi-
ronment. Dispose of them in compliance with
the relevant laws.
- 14 -
C
C
E
D
ENGLISH