For proper installation, we remind you that:
- the boiler must not be installed over a kitchen or any other cooking
equipment
- minimum spaces are to be left in order to allow maintenance
operations: at least 5,0 cm every side and 20 cm under the boiler
- it is forbidden to leave inflammable substances in the room
- suitably insulate heat-sensitive walls (e.g.: in wood).
Support plate and integrated pre-installation template are provided for
with the boiler (Fig. 1.1).
Mounting instructions:
- fix the boiler support plate (F) with the template (G) to the wall and
use a plumb to check that it is perfectly horizontal
- trace out 4 holes (Ø 6 mm) for fixing the boiler support plate (F) and
2 holes (Ø 4 mm) for fixing the pre-installation template (G)
- make sure all the measurements are correct, then drill holes in the
wall using a drill and point with the diameter given previously
- fix the plate to the wall by the supplied anchor screws
- make hydraulic connections.
After installing the boiler, the screws D1 (Fig. 1.2) can be removed. After
installing the boiler and connecting it to the water and gas supplies, fit
the lower cover (A-B, Fig. 1.3) so that its hooks slip into the relative slots
in the lower part of the boiler. Fix the lower cover with the screw C (Fig.
1.4) contained in the documentation envelope in the boiler.
PUMP DUTY
Exclusive Green E boilers is equipped with high efficiency electronic
circulators and digital control. Its main features and the methods for
setting the desired operation are described below.
Prevalenza residua disponibile all'impianto circolatori UPM3 ZB 15-60 e FLEX AS 6m
Circulator residual head 6 m
[codd. 20092011 - 20090619/20 e 20091499- 20091500/1/2 impostati a 6m]
700
650
600
550
500
450
400
350
modulation area
300
250
200
150
100
50
0
0
100
200
300
400
Prevalenza Impianto
UPM3 FLEX 15-60 P90=100 (mbar)
Prevalenza residua disponibile all'impianto circolatori UPM3 ZB 15-50 e FLEX AS 5m
Circulator residual head 5 m
[codd. 20087320 e 20091499 - 20091500/1/2 impostati a 5 m]
700
650
600
550
500
450
400
350
300
modulation area
250
200
150
100
50
0
0
100
200
300
400
Prevalenza Impianto
UPM3 FLEX AS 15-50 AO RC RO P90=100 (mbar)
User interface
The user interface is composed of a key (A), a bi-colour red/green LED
(B) and four yellow LEDs (C) in a line.
The user interface allows you to display the operating performance
(operating status and alarm status) and set the operating modes of the
circulator.
The performances, indicated by the LEDs (B) and (C) are always visible
during the normal operation of the circulator, while the settings are carried
out by pressing the key (A).
500
600
700
800
900
1000
Portata impianto [l/h]
Capacity [l/h]
Prevalenza Impianto
UPM3 FLEX 15-60
P90=60
(mbar)
500
600
700
800
900
1000
Capacity [l/h]
Portata impianto [l/h]
Prevalenza Impianto
UPM3 FLEX 15-50
P90=60...
Cleaning the system and characteristics of heating circuit water
After installing a new system or replacing a boiler, clean the heating
system. To ensure the product works correctly, after cleaning, additivating
and/or chemically treating the system (e.g.: anti-freeze, film-formers,
etc.), make sure the characteristics of the water satisfy the parameters
indicated in the table.
Parameters
pH value
Hardness
Appearance
Fe
Cu
Prevalenza residua disponibile all'impianto circolatori UPM3 ZB 15-70 e FLEX AS 7m
700
650
600
550
500
450
400
350
300
250
200
150
100
50
1100
1200
0
0
100
200
700
650
600
550
500
450
400
350
300
250
200
150
100
50
0
1100
1200
0
100
200
Unit of
Hot water
measurement
circuit
-
7–8
°F
-
-
-
mg/kg
0,5
mg/kg
0,1
Circulator residual head 7 m
[codd. 20091499 - 20091500/1/2 impostati a 7 m]
modulation area
300
400
500
600
700
800
Capacity [l/h]
Portata impianto [l/h]
Prevalenza Impianto
UPM3 FLEX 15-70 AO AC RO P90=100 (mbar)
Prevalenza residua disponibile all'impianto circolatori FLEX AS
Circulator residual head 4 m
codd. 20091499 - 20091500/1/2 a impostati a 4 m
modulation area
300
400
500
600
Capacity [l/h]
Portata impianto [l/h]
Prevalenza Impianto
UPM3 FLEX 15-70 P90=100 (mbar)
A
B
ENGLISH
Filling
water
-
<15
clear
-
-
900
1000
1100
1200
1300
Prevalenza Impianto
UPM3 FLEX 15-70 P90=60...
700
800
900
1000
Prevalenza Impianto
UPM3 FLEX 15-40 P90=60
(mbar)
C
5

Publicidad

Tabla de contenido
loading

Tabla de contenido