ELECTRICAL CONNECTION (0G0PE1-0G0PE2-1G0PE1-1G0PE2-2G0PE2)
Important
The connection must be made by author-
ised, skilled personnel, in accordance with
the relevant legal requirements, using ap-
propriate and specified materials. The ap-
pliance is supplied with operating voltage
400V/3N, which cannot be switched to other
values (see attached wiring diagrams).
Caution - warning
Before doing any work, cut off the mains elec-
tricity supply.
Connect the appliance to the mains electricity sup-
ply as follows.
1 - If not already present, install a circuit-breaker
(A) with overload cutout and differential
safety breaker close to the appliance.
2 - Undo the screws (C) and remove the con-
trol panel (B).
IT
GB
DE
TESTING OF THE APPLIANCE
FR
Important
ES
Before it is put into service, the system
must be tested to check the operating con-
ditions of every single component and
identify any malfunctions. In this stage, it is
important to check that all health and safety
requirements have been complied with in
full.
To test the system, make the following checks.
1 - Check that the mains voltage is the same as
that of the appliance.
English
A
C
B
3 - Connect the circuit-breaker (A) to the terminal
board (D) of the appliance as shown in the dia-
gram and in the electrical system diagram at
the back of the manual. Use a cable with at
least H05RN-F characteristics.
Important
When connecting, take care to connect the
neutral and earth lines.
4 - Replace the control panel (B) on completion of
the operation.
2 - Operate the appliance's circuit-breaker to
check the electrical connection.
3 - Check that the safety device is operating cor-
rectly.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
- 14 -
D