Descargar Imprimir esta página

Maintenance And Storage - IKAR IK L Manual De Instrucciones

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 21
checking the connectors for:
rust and pitting
cracks
distortion / disfigurement
excessive wear
functioning freely and correctly
correct alignment of the gate
checking any screwed triangular link interconnection within a lanyard for:
rust and pitting
cracks
distortion / disfigured
excessive wear
secure and tight connection
checking any plastic primary or secondary components for:
correct placement
cracks
distortion / disfigurement
excessive wear
damage
If any defects or damage is identified the lanyard should not be used. It should be taken to a competent person responsible
for the detailed recorded inspections for a thorough visual and Tactile examination.
Detailed recorded inspections should:
be carried out by a trained competent person to ensure the safety and integrity of the
lanyard;
recorded in the record table contained within these User Instructions;
be carried out on a regular basis. The frequency of the detailed recorded inspection should be deemed through Risk
Assessment taking into account legislation, equipment type, frequency of use, and environmental conditions, which
may accelerate the rate of deterioration and physical damage
be carried out at least every 12 months regardless of usage.
Maintenance of this IKAR GmbH Lanyard must only be carried out by a trained and competent person, who will:
ensure that NO alterations to the lanyard are made
clean the product using the following procedure:
using only warm water
ENGLISH
Detailed Recorded Inspections

Maintenance and Storage

19

Publicidad

loading