Disposal Instructions - Air Liquide Respireo SOFT Nasal Manual De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 20
logging on to www.device.airliquidehealthcare.com or by contacting
your dealer.
8 - REASSEMBLY THE MASK (Fig.E)
8.1 Insert the swivel connector (d) in the elbow (c) (Fig.E1).
8.2 Insert the elbow (c) in the mask frame (b) (Fig.E2).
8.3 If the buckle (f) has be detached from the headgear, insert the
straps located over the head into it by keeping the light color side
of the straps facing out.
8.4 Insert the two upper straps into the slots located on the forehead
support of the mask frame (b) (Fig.E3).
Note: Do not open the headgear hooks in order to do not readjust
the straps.
8.5 Attach the cushion (a) to the mask frame (b) keeping the cushion
triangle alligned with the mask frame triangle (Fig.E4).
Note: Be sure that the lines on the mask frame (b) and on
the cushion (a) are aligned; if not, the cushion is not mounted
properly. Please mount the cushion again.
9 - TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSES SOLUTIONS
• No air air
• Flow generator is
comes out of
off or not working
the vent ports
properly
• Difficulty of
• Patient circuit tube
breathing
is not well inserted
• The mask is
• Vent ports are or
noisy
partially obstructed
• Mask is not properly
assembled
• Mask is not correctly
positionned
ENGLISH
• Switch on the flow
generator
• Regulate the flow generator
• Connect the tube to the flow
generator and mask.
• Clean the vent ports with a
soft bristle brush
• Disassemble the mask,
then reassemble according
to the instruction
• Refit or reposition
the mask and set the
headgear according the
instruction of fitting
PROBLEM
POSSIBLE CAUSES SOLUTIONS
• Mask leaks
• Mask is not
around the
positioned correctly
face
• Headgear straps
are not correctly set
(over tighthen or too
loose).

10 - DISPOSAL INSTRUCTIONS

The components of the mask are made of the following materials and
must be disposed of in accordance with the applicable laws.
COMPONENT
Cushion (a)
Mask frame (b)
Elbow (c)
Swivel connector(d)
Headgear (e)
Buckle (f)
11 - TECHNICAL SPECIFICATIONS
PRESSURE-FLOW CURVE
14
• Refit or reposition the
mask and set the headgear
according the instruction of
fitting
MATERIAL
Silicone + Polybutylene
Polycarbonate + Silicone
Polycarbonate
Nylon
Nylon+Poliurethane
Nylon