A variety of optional installation kits are available for
arranging appliances in banks:
G)"Over cupboard" installation kit
H)"Bridge" installation kit
GAS CONNECTION
Important
Those authorised to carry out this opera-
tion must have experience acquired and
certified in the specific sector, must make
IT
the connection to the proper standards,
and must comply with all the relevant regu-
GB
lations and legislation. Once the connec-
tion has been made, before the appliance is
DE
put into operation a general check must be
made to ensure there are no gas leaks.
FR
To make the connection, connect the mains line to
the appliance's connection pipe, fitting a shut-off
ES
tap (A), to allow the gas supply to be cut off when
necessary.
Important
The tap (A), not supplied with the appliance,
must be installed in an easily accessible
position and its status (on or off) must be
obvious at a glance.
English
G
- 14 -
H
A
Important
The gas supply pipe must comply with the
national requirements in force and must be
periodically examined and replaced if ne-
cessary.
IDM-39614501300.tif
IDM-39603601210.tif