Hood Preparation
Note: Optional stainless steel backsplashes are available
in widths to match all pro wall hoods. Before installing the
hood, the backsplash should be installed first. See
directions accompanying the backsplash for full installation
instructions.
Discharge Direction
The hood can be mounted on a wall or suspended from a
cabinet. Both vertical and horizontal discharge are possible
with either mounting method.
This opening
This opening
This opening
is covered
is covered
is covered
for horizontal
for horizontal
for horizontal
discharge
discharge
discharge
The hood is shipped ready for vertical discharge. To
change to horizontal discharge, move the discharge cover
shown in Figure 4 to the top of the hood. The plate is held
in place by (4) screws.
Hood Transition
The supplied transition mounts to the top or rear of the
hood, depending on the discharge direction.
10"
(254 mm)
Duct
1" (25.4 mm)
screw x 2
"
"
(110 mm)
(110 mm)
(110 mm)
5
5
4
4
/
/
16 16
16
English 8
This opening
This opening
This opening
is covered
is covered
is covered
for vertical
for vertical
for vertical
discharge
discharge
discharge
Figure 4: Discharge Direction
Figure 5: Transition
21¾"
21¾"
21¾"
(553 mm)
(553 mm)
(553 mm)
"
"
"
1
1
1
11
11
11
/
/
/
16
16
16
(43 mm)
(43 mm)
(43 mm)
Figure 6: Transition Cutout Dimensions
Assembly of the Transition
A minimum height clearance of 6'' (152 mm) is needed
above the hood for transition mounting. See "General
Information" on page 3 for overall hood dimensions.
1. Depending on direction of discharge, align mounting
holes at base of transition with the mounting holes of
the ½'' (13 mm) flange located at the top or rear of the
hood.
2. Fasten transition to hood using (2) 1'' (25.4 mm) sheet
metal screws included with hood.
3. Seal connection between transition and hood with
aluminum tape.
4. Remove tape holding damper closed.
4¼"
4¼"
4¼"
(108 mm)
(108 mm)
(108 mm)
Figure 7: Transition Connection