7.
PROGRAMMING Appia V
7.1
PROGRAMMING
DOSES
To access the programming units, proceed as
follows:
NOTE: the procedure can be carried out with
the machine on.
• To enter the programming function for each
group, it is necessary to hold down the con-
tinued delivery key
• The delivery keys will begin to flash.
• Accessing the programming mode for the
first group also enables the setting mode for
the machine's operating parameters.
7.2
PROGRAMMING COF-
FEE DOSES
To programme the amount of water for each of
the delivery keys, proceed as follows:
• fill the filter holder with the right amount of
coffee (the double or single filter holder can
be used, according to the key to be pro-
grammed).
• Place the filter holder in the group.
• Press one of the delivery keys:
• The machine will begin to dispense and
once the required quantity has been delive-
red, press the continued key
38
• Delivery will cease and the selected dose
key will switch off (the other keys will conti-
nue to flash).
• Press the continued key
the programming function or to continue
programming other dose keys
NOTE: This procedure can be used for all
groups on the machine, although it
must be performed on one group at a
time; the other groups will continue to
operate as normal.
for 5 seconds
7.3
PROGRAMMING HOT
WATER
• Use the relevant procedure to enter the pro-
gramming function.
• Press the hot water selection key
• Hot
water
• Decide the required amount of hot water
and then press the
• Press the continued key
the programming function or to continue
programming other selection keys.
7.4
PROGRAMMING THE
CUP WARMER (optio-
nal)
• Enter the programming mode for the first
group following the usual procedure.
.
.
• Press the cup warmer select key
to exit
.
delivery
will
begin.
key
again
to exit
.
• The delivery buttons for the first and second
group will respectively show the automatic
switch on and off times, while the continuous
keys
for the first and second group
will flash.
As shown in the table, each of the delivery
keys has an associated value; the switch on
time for the cup warmer is given by sum-
ming the values for the lit keys of the first
group. The same calculation method is
used for the switch off time of the cup war-
mer, using the keys of the second group.
Key
Group 1
(on time)
2 min.
4 min.
8 min.
16 min.
Group 2
(off time)
5 min.
10 min.
20 min.
40 min.

Publicidad