OPERATION
5. With charger's power supply cord unplugged,
connect battery charger into machine's charging
receptacle as shown. Flip up hood support stand
and rest hood on stand (Figure 53).
FIG. 53
6. Plug charger's power supply cord into a grounded
wall outlet (Figure 54).
Grounded
3 Hole Outlet
Ground Pin
(120V)
FIG. 54
WARNING: Keep Sparks And Open Flame
Away. Keep Battery Hood Open When Charging.
NOTE: Once the charger is connected, machine
becomes inoperable.
7. Charger will automatically begin charging and shut
off when fully charged.
8. When disconnecting charger, always unplug
charger from wall outlet first.
9. After charging batteries, check electrolyte level (A)
in each battery cell. Add just enough distilled water
to bring electrolyte level (A) up to 1cm (0.38 in.)
from bottom of fill rings (B) (Figure 55). DO NOT
OVERFILL.
B
FIG. 55
22
Grounded Outlet
Grounding
Edge/hole
(230V)
A
Home
Find... Go To..
MACHINE MAINTENANCE
To keep machine in good working condition, simply
follow daily, weekly and monthly maintenance
procedures.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface, turn off machine,
and set parking brake, if equipped.
WARNING: Disconnect Battery Cables Before
Servicing Machine.
ATTENTION: Contact an Authorized Service
Center for machine repairs. Machine repairs
performed by other than an authorized person will
void your warranty.
DAILY MAINTENANCE
(Every 4 Hours of Use)
1. Drain and flush out tanks with clean water
(Figure 56).
FIG. 56
2. Remove recovery tank plug and flush intake
opening with water (Figure 57).
FIG. 57
Tennant 5400 (05–03)