Equipping The Cable Assembly; Mounting The Machine Side Connection - Abicor Binzel ABIROB W Manual De Instrucciones

Ocultar thumbs Ver también para ABIROB W:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

®
ABIROB
W

6.3 Equipping the cable assembly

1
10
®
1
ABIROB
W torch neck
®
2
ABIROB
W cable assembly
3
Air-blast hose
4
Connecting nut of central connector
Fig. 6
Equipping the hose assembly

6.4 Mounting the machine side connection

2
9
5
Central connector
6
Support sleeve
7
Complete liner
NOTICE
• Select the proper wire type and the related wire guide for your
application.
• For cutting the wire size and for correct mounting, please observe the
following chapters:
 See 9 Maintenance and cleaning on page EN-17
1 Lay down the cable assembly (2) straight.
2 Slide complete liner (7) from central connector (5) into the torch neck (1)
as far as it will go.
If required, connect the EMERGENCY STOP cable (9) of the CAT robot
mount (10) to the hose assembly (2) .
 See Fig. 6 Equipping the hose assembly on page EN-13
Check once again whether the wire guide has been fitted correctly.
1 Mount central connector (5) to the wire feeder and secure it with the
connection nut (4).
2 Fasten the air-blast hose (8) to the air-blast and spraying unit or the air-blast
valve. Seal the connection gas-tight if the "Air-blast" option is not used.
6 Putting into operation
3
8
8
9
10 CAT robot mount
4
Wire feed
EMERGENCY STOP cable
EN - 13
5
6
7

Publicidad

Tabla de contenido
loading

Tabla de contenido