13. TABLE OF SC-922 FUNCTION ITEMS IN ACCORDANCE WITH THE
ADDITIONAL DEVICES
Additional
Function
Function item
device
No.
2-pitch
148
2-pitch output during
device
reverse feed stitch-
ing at start or at end
149
Inversion of 2-pitch
output during output-
ting alternate vertical
amount
150
2-pitch initial output
Alternate
144
Setting of number of
vertical
stitches of automatic
amount
release of alternate
change
vertical output
device
146
Selection of alternate
vertical output after
thread trimming
147
Alternate vertical
initial output
Needle
156
Selection of needle
thread
thread clamp switch
clamp
function
device
Starting
Setting
level
range
User
0, 1
0 : Invalid
1 : 2-pitch is output during controlling
reverse feed stitching at start or end.
User
0, 1
0 : Invalid
1 : State of 2-pitch output is inversely
output, synchronizing with alternate
vertical output.
User
0, 1, 2
0 : When the power is ON, reset is made
with the status of the previous power
OFF.
1 : When the power is ON, 2-pitch output
is turned OFF.
2 : When the power is ON, 2-pitch output
is turned ON.
User
0,
0 : Automatic release is invalid.
1 to 30
1 to 30 : Release of alternate vertical out-
stitches
User
0, 1, 2
0 : Invalid
1 : Alternate vertical output is forcibly
turned OFF after thread trimming.
2 : Alternate vertical output is forcibly
turned ON after thread trimming.
User
0, 1, 2
0 : When the power is ON, reset is made
with the status of the previous power
OFF.
1 : When the power is ON, alternate verti-
cal output is turned OFF.
2 : When the power is ON, alternate verti-
cal output is turned ON.
User
0, 1, 2
0 : When the needle clamp switch is
turned ON, this function is enabled.
1 : Needle clamp function will be disabled.
2 : Needle clamp function is enabled forci-
bly.
– 20 –
Description
put is automatically performed by
the number of stitches.
Applicable
model
LU-2212N-7
LU-2220N-7
LU-1500N-7
LU-1520NC-7
LS-1342-7
DNU-1541-7
PLC-1700-7
LU-2200N-7
LU-2220N-7