3
Technical Data
152mm X 165mm X
Size
178mm
(6" X 6.5" X 7.0")
Weight
1.2 kg (2.6lbs)
Minimum
Dispense
0.020 Seconds
Time
Input Voltage
24VDC
Rated Power
10W
Air Input
100 psi (6.9 bars) Max.
Pollution
II
Degree
Installation
I
Category
Altitude up to 2,000m
Indoor Use
(6,562ft)
Operating
0˚C to 50˚C (32˚F to
Temperature
122˚F)
4
Installation
Use 5 micron Filter –Regulator –Loctite 985397 or
equivalent for inlet air supply
3
1
2
5
4.1 10ml or 30ml syringe adapter attaches to Pulsed Air
Outlet (7) and syringe barrel.
80% for temperature up to
Max.
31˚C (87.8˚F) Decreasing
Relative
linearly to 50% relative
Humidity
humility at 40˚C (104˚F)
Air Output
0-100 psi (0-6.9 bars)
Maximum
Dispense
99.999 seconds
Time
Vacuum
406mm (16") of Hg
Timer
0.020 - 99.999 seconds
Cycle Mode
Timed, Incremental, Manual
Timing
Repeat
+/- 0.001%
Tolerance
Cycle Rate
600 cycles/min
LCD
16 X 2 display segments
Storage
-10˚C to 60˚C (14˚F to
Temperature
140˚F)
Items
Description
1
To Air Source
Air Filter –sold
2
separately
3
Power Adapter
Foot Switch
4
4
5
Syringe Adapter
Fig. 4.1
6