5.1 Set up Instructions – Manual Dispense Cycle Setting
The Manual Mode allows the unit to pulse for the duration
that the foot switch is depressed. It is typically used to start up and
purging through a dispense needle.
The unit is factory pre-set with a dispense time of 0.1
seconds. Manual mode will not function unless there is time set
in the time display. (00.000 time setting will not allow the unit to
dispense in manual mode)
5.1.1 Turn on the unit by pressing the Power button (1).
5.1.2 Press the Mode button (2) until Manual Mode appears
on the display.
5.1.3 Turn up the air pressure by rotating the Air Pressure
Regulator knob (6) until the desired pressure is indicated on
the Air Pressure Gauge (5).
5.1.4 After filling the barrel or using pre-packaged adhesive,
attach the syringe to the syringe adapter. Make certain that
the syringe locks into place.
5.1.5 Connect the plug end of the receiver head assembly to
the Air Dispense Outlet (7).
5.1.6 If vacuum "suck back" is needed, rotate the Vacuum
Regulator (8) counter clockwise until the desired vacuum
pressure is obtained.
5.1.7 Press and hold the Footswitch to activate the dispense
cycle. (The Manual Mode is now activated)
5.2 Dispense Cycle Setting – See Figure 5.1
Push the Mode button (2) to select Timed Mode or
Incremental Mode.
• Timed Mode: Allows the unit to dispense for the
the complete amount of time set on the timer
when the foot switch is initiated
• Incremental Mode: Allows the unit to dispense
for as long as the foot pedal is depressed and will
continue till the set time is reached. This allows a
7